7750 Sr-A4 Chassis Slot Allocation; Figure 2 7750 Sr-A4 Chassis Slot Identification - Alcatel-Lucent 7750 SR-a4 Installation Manual

Service router
Table of Contents

Advertisement

7750 SR-a Chassis Features

7750 SR-a4 Chassis Slot Allocation

26
This section describes the slot allocations for each type of chassis component.
identifies the slots and the components.
Figure 2: 7750 SR-a4 Chassis Slot Identification
Fan Tray
Slot 1
Slot 2
Slot 3
Slot 4
As shown in
Figure
2, slots 1 to 3 make up the 7750 SR-a4 forwarding complex. The
forwarding complex has a single IOM-a and up to four MDA-a cards with a total forwarding
capacity of 100 Gb/s.
MDA-a and MDA-aXP cards occupy a half of a chassis slot. Slot one (at the top of the
chassis) supports up to two MDA-a cards. Slot two also supports up to two MDA-a cards. The
adapter cards are numbered individually as MDA-a 1/1, MDA-a 1/2, MDA-a 1/3, and MDA-
a 1/4.
MDA-a slot 1/1 and 1/2 are XP-capable, meaning that they support 100 Gb/s MDA-aXPs.
These slots support up to 100 Gb/s full-duplex bandwidth. The remaining two MDA-a slots
support 25 Gb/s full-duplex bandwidth. MDA-a cards must be ordered separately from the
chassis. An impedance panel must be installed in any empty MDA-a slot. See
for more information.
Note:
A 100 Gb/s MDA-aXP card can operate in a 25 Gb/s slots, but the slot will be
oversubscribed. If you install a 100 Gb/s MDA-aXP card in a 25 Gb/s slot, the maximum
line rate is 25 Gb/s.
A 25 Gb/s MDA-a card can operate in 100 a Gb/s slot, but the slot will be
undersubscribed. If you install a 25 Gb/s MDA-a card in a 100 Gb/s slot, the maximum
line rate is 25 Gb/s.
MDA-XP 1/1
MDA 1/3
IOM 1
CPM A
PSU 1
PSU 2
7750 SR-a4 and SR-a8 Installation Guide
Air Filter
MDA-XP 1/2
MDA 1/4
CPM B
PSU 3
PSU 4
Figure 2
Forwarding
Complex
24538
MDA-a Cards