2
3
1
7750 SR-a4 and SR-a8 Installation Guide
Figure 24: Attaching the Chassis Ground Connector
1
Key
Description
1
Chassis ground studs on the chassis mounting flange
2
Two 10-32 KEP nuts for the ground lug (supplied in the accessory kit)
3
Two-hole ground lug and copper wire cable
Required tools and hardware:
•
wire stripping tool
•
wire cutter
•
crimping tool, Burndy Die Index #49
•
3/8 in. hex torque driver for #10 hex nut
•
copper ground wire cable (minimum #8 AWG)
To make the chassis ground connection:
Step 1. Run a single length of minimum #8 AWG wire from the ground point (building
ground or equipment ground bus) to the chassis ground studs. When routing the
cable, ensure that there is enough extra wire to form a service loop at the chassis
end in order to facilitate maintenance.
Table 39: Ground Wire Connection Parts
Installing the 7750 SR-a Chassis
24551
87