Table 16 7750 Sr-A8 Environmental Specifications - Alcatel-Lucent 7750 SR-a4 Installation Manual

Service router
Table of Contents

Advertisement

Parameter
Earthquake
2
Pollution degree
Rated voltage (DC)
Operating voltage range (DC)
Rated voltage (AC)
Operating voltage range (AC)
Parameter
Normal operating temperature
Short-term operating temperature
Maximum altitude
Normal operating relative humidity
Short-term operating relative humidity
Acoustic noise level
Shock and vibration
Earthquake
2
Pollution degree
7750 SR-a4 and SR-a8 Installation Guide
Table 15: 7750 SR-a4 Environmental Specifications (Continued)
Notes:
1.
Short-term refers to no more than 96 consecutive hours per occurrence and no more than 15 occurrences in
a one-year period.
2.
Pollution degree is as defined in IEC 60950. Pollution Degree 2 applies where there is only non-conductive
pollution that might temporarily become conductive due to occasional condensation.
Table 16: 7750 SR-a8 Environmental Specifications
1
1
Description
Suitable for high-risk areas (Zone 4/California, for
short-duration disturbance)
2
–48 VDC
–40 to –72 VDC
120 or 240 VAC
90 to 264 VAC
Description
23 to 113ºF (–5 to 45ºC)
23 to 131ºF (–5 to 55ºC)
13 000 ft (3962.4 m)
5 to 90% (non-condensing)
5 to 93% (non-condensing)
78 dBA at 27ºC (80.6ºF). Fan speed is adaptive.
Very low levels for continuous duration disturbance (similar
to modern office Building, for example)
Shock: 3 g half sine 11 ms
Vibration: 0.1 g from 5 to 100 Hz
Suitable for high-risk areas (Zone 4/California, for
short-duration disturbance)