APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 59 of 60)
ADDR
REGISTER NAME
EADB
PMU 1 df/dt Trigger Pickup Time
EADC
PMU 1 df/dt Trigger Dropout Time
EADD
PMU 1 df/dt Trigger Block (3 items)
EAE0
PMU 1 df/dt Trigger Target
EAE1
PMU 1 df/dt Trigger Events
Phasor Measurement Unit Frequency Trigger (Read/Write Setting)
EB00
PMU 1 Frequency Trigger Function
EB01
PMU 1 Frequency Trigger Low Frequency
EB02
PMU 1 Frequency Trigger High Frequency
EB03
PMU 1 Frequency Trigger Pickup Time
EB04
PMU 1 Frequency Trigger Dropout Time
EB05
PMU 1 Frequency Trigger Block (3 items)
EB08
PMU 1 Frequency Trigger Target
EB09
PMU 1 Frequency Trigger Events
Phasor Measurement Unit Power Trigger (Read/Write Setting)
EB28
PMU 1 Power Trigger Function
EB29
PMU 1 Power Trigger Active
EB2A
PMU 1 Power Trigger Reactive
EB2B
PMU 1 Power Trigger Apparent
EB2C
PMU 1 Power Trigger Pickup Time
EB2D
PMU 1 Power Trigger Dropout Time
EB2E
PMU 1 Power Trigger Block (3 items)
EB31
PMU 1 Power Trigger Target
EB32
PMU 1 Power Trigger Events
Phasor Measurement Unit Voltage Trigger (Read/Write Setting)
EB54
PMU 1 Voltage Trigger Function
EB55
PMU 1 Voltage Trigger Low Voltage
EB56
PMU 1 Voltage Trigger High Voltage
EB57
PMU 1 Voltage Trigger Pickup Time
EB58
PMU 1 Voltage Trigger Dropout Time
EB59
PMU 1 Voltage Trigger Block (3 items)
EB5C
PMU 1 Voltage Trigger Target
EB5D
PMU 1 Voltage Trigger Events
Phasor Measurement Unit One-shot Command (Read/Write Setting)
EB82
PMU One-shot Function
EB83
PMU One-shot Sequence Number
EB84
PMU One-shot Time
Phasor Measurement Unit Test Values (Read/Write Setting)
EB86
PMU 1 Test Function
EB87
PMU 1 Phase A Voltage Test Magnitude
EB89
PMU 1 Phase A Voltage Test Angle
EB8A
PMU 1 Phase B Voltage Test Magnitude
EB8C
PMU 1 Phase B Voltage Test Angle
EB8D
PMU 1 Phase C Voltage Test Magnitude
EB8F
PMU 1 Phase C Voltage Test Angle
EB90
PMU 1 Auxiliary Voltage Test Magnitude
EB92
PMU 1 Auxiliary Voltage Test Angle
EB93
PMU 1 Phase A Current Test Magnitude
EB95
PMU 1 Phase A Current Test Angle
EB96
PMU 1 Phase B Current Test Magnitude
EB98
PMU 1 Phase B Current Test Angle
EB99
PMU 1 Phase C Current Test Magnitude
EB9B
PMU 1 Phase C Current Test Angle
EB9C
PMU 1 Ground Current Test Magnitude
GE Multilin
RANGE
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
20 to 70
20 to 70
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0.25 to 3
0.25 to 3
0.25 to 3
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0.25 to 1.25
0.75 to 1.75
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 59
0 to 235959
0 to 1
0 to 700
-180 to 180
0 to 700
-180 to 180
0 to 700
-180 to 180
0 to 700
-180 to 180
0 to 9.999
-180 to 180
0 to 9.999
-180 to 180
0 to 9.999
-180 to 180
0 to 9.999
D60 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
Hz
0.01
F001
Hz
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
pu
0.001
F001
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F001
---
1
F050
---
1
F102
kV
0.01
F003
°
0.05
F002
kV
0.01
F003
°
0.05
F002
kV
0.01
F003
°
0.05
F002
kV
0.01
F003
°
0.05
F002
kA
0.001
F004
°
0.05
F002
kA
0.001
F004
°
0.05
F002
kA
0.001
F003
°
0.05
F002
kA
0.001
F004
DEFAULT
10
100
0
0 (Self-reset)
0 (Disabled)
B
0 (Disabled)
4900
6100
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
1250
1250
1250
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
800
1200
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
1
0
0 (Disabled)
50000
0
50000
-120
50000
120
50000
0
1000
-10
1000
-130
1000
110
0
B-67