GE D60 Instruction Manual page 618

Line distance protection system ur series
Hide thumbs Also See for D60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 58 of 60)
ADDR
REGISTER NAME
Phasor Measurement Unit Recording (Read/Write Setting)
E4DC
PMU 1 Recording Rate
E4DD
Reserved
E4DE
PMU 1 No Of Timed Records
E4DF
PMU 1 Trigger Mode
B
E4E0
PMU 1 Timed Trigger Position
E4E1
Reserved
E4E2
PMU 1 Record PHS-1 (14 items)
E4F0
PMU 1 Record PHS-x Name (14 items)
E560
PMU 1 Record A-CH-x (8 items)
E568
PMU 1 Record A-CH-x Name (8 items)
E5A8
PMU 1 Record D-CH-x (16 items)
E5B8
PMU 1 Record D-CH-x Name (16 items)
Phasor Measurement Unit Network Reporting Configuration (Read/Write Setting)
EA4C
PMU Network Reporting Function
EA4D
PMU Network Reporting ID Code
EA4E
PMU Network Reporting Rate
EA4F
PMU Network Reporting Style
EA50
PMU Network Reporting Format
EA51
PMU Network PDC Control
EA52
PMU TCP port number
EA53
PMU UDP port number 1
EA54
PMU UDP port number 2
Phasor Measurement Unit Basic Configuration (Read/Write Setting)
EA58
PMU 1 Function
EA59
PMU 1 IDcode
EA5A
PMU 1 STN
EA62
PMU 1 Source
EA63
PMU 1 Post-Filter
Phasor Measurement Unit Calibration (Read/Write Setting)
EA88
PMU 1 Va Calibration Angle
EA89
PMU 1 Vb Calibration Angle
EA8A
PMU 1 Vc Calibration Angle
EA8B
PMU 1 Vx Calibration Angle
EA8C
PMU 1 Ia Calibration Angle
EA8D
PMU 1 Ib Calibration Angle
EA8E
PMU 1 Ic Calibration Angle
EA8F
PMU 1 Ig Calibration Angle
EA90
PMU 1 Sequence Voltage Shift Angle
EA91
PMU 1 Sequence Current Shift Angle
Phasor Measurement Unit Triggering (Read/Write Setting)
EAB0
PMU 1 User Trigger
Phasor Measurement Unit Current Trigger (Read/Write Setting)
EAB4
PMU 1 Current Trigger Function
EAB5
PMU 1 Current Trigger Pickup
EAB6
PMU 1 Current Trigger Pickup Time
EAB7
PMU 1 Current Trigger Dropout Time
EAB8
PMU 1 Current Trigger Block (3 items)
EABB
PMU 1 Current Trigger Target
EABC
PMU 1 Current Trigger Events
Phasor Measurement Unit df/dt Trigger (Read/Write Setting)
EAD8
PMU 1 df/dt Trigger Function
EAD9
PMU 1 df/dt Trigger Raise
EADA
PMU 1 df/dt Trigger Fall
B-66
RANGE
0 to 10
---
1 to 128
0 to 1
1 to 50
---
0 to 14
---
0 to 65535
---
0 to 65535
---
0 to 1
1 to 65534
0 to 11
0 to 1
0 to 1
0 to 1
1 to 65535
1 to 65535
1 to 65535
0 to 1
1 to 65534
---
0 to 5
0 to 3
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-5 to 5
-180 to 180
-180 to 180
0 to 65535
0 to 1
0.1 to 30
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0.1 to 15
0.1 to 15
D60 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F544
---
1
F001
---
1
F001
---
1
F542
0 (Auto Overwrite)
%
1
F001
---
1
F001
---
1
F543
---
---
F203
GE-UR-PMU-PHS 1
---
1
F600
---
---
F203
AnalogChannel 1
---
1
F300
---
---
F203
---
1
F102
---
1
F001
---
1
F544
---
1
F546
---
1
F547
---
1
F102
---
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
---
F203
---
1
F167
---
1
F540
1 (Symm-3-point)
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
0.05
F002
°
30
F002
°
30
F002
---
1
F300
---
1
F102
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
Hz/s
0.01
F001
Hz/s
0.01
F001
DEFAULT
3 (10/sec.)
0
3
10
0
1 (Va)
0
0
Dig Channel 1
0 (Disabled)
1
3 (10/sec.)
0 (Polar)
0 (Integer)
0 (Disabled)
4712
4713
4714
0 (Disabled)
1
"GE-UR-PMU"
0 (SRC 1)
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
1800
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
25
25
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents