Connection to screw terminals

1.
Loosen the lid clip and unscrew the lid of the enclosure.
2.
Unscrew and lift up the digital display. (Loosen each screw two turns before
completely loosening both, to keep the rubber retaining rings in place.)
3.
Strip the cable jacket for approximately 70 mm (2.75") from the end of the power
cable, and thread the wires through the gland.
4.
Connect the wires to the Profibus PA/power connection terminals shown below;
polarity is not important. The terminal can be removed and replaced to simplify
connection.
7ML19985JJ03
digital display
lid clip
gland
power
cable
removable
terminal block
for alarm output /
solid-state switch
alarm output
solid-state switch
sensor
Pointek CLS200/300 Digital – OPERATING INSTRUCTIONS
test
input
PROFIBUS PA
Connect the power cable to
these terminals. (Polarity is
not important.)
power cable
removable
terminal block
for Profibus PA/
power
connection