Maximum permissible ambient temperature range in potentially explosive
atmospheres:
–40 °C to maximum +85 °C (–40 ºF to maximum 185 ºF ): T4
–40 °C to maximum +40 °C (–40 °F to maximum 104 °F): T6
•
Maximum permissible process temperature range in potentially explosive
atmospheres:
–40 °C to maximum +200 °C (–40 ºF to maximum +392 ºF )
–40 °C to maximum +400 °C (–40 ºF to maximum +752 ºF ):
high temperature version
Operating the CLS300 Flameproof / explosion proof
configuration in hazardous areas
ATEX
•
Maximum permissible ambient temperature range in potentially explosive
atmospheres:
–40 °C to maximum +85 °C (–40 °F to maximum +185 °F): T4
–40 °C to maximum +85 °C (–40 °F to maximum +185 °F): T5
–40 °C to maximum +70 °C (–40 °F to maximum +158 °F): T6
•
Maximum permissible process temperature range in potentially explosive
atmospheres:
For category II 1 G:
–20 ºC to maximum +60 °C (–4 ºF to maximum +140 ºF )
For category II 2 G:
–40 °C to maximum +135 °C (–40 °F to maximum +275 °F): T4
–40 °C to maximum +100 °C (–40 °F to maximum +212 °F): T5
–40 °C to maximum +80 °C (–40 °F to maximum +176 °F): T6
CSA/FM
•
Maximum permissible ambient temperature range in potentially explosive
atmospheres:
–40 °C to maximum +85 °C (–40 ºF to maximum +185 ºF ): T4
–40 °C to maximum +40 °C (–40 °F to maximum +104 °F): T6
•
Maximum permissible process temperature range in potentially explosive
atmospheres:
–40 °C to maximum +200 °C (–40 ºF to maximum+ 392 ºF )
–40 °C to maximum +400 °C (–40 ºF to maximum +752 ºF ):
high temperature version
Page 94
Pointek CLS200/300 Digital – OPERATING INSTRUCTIONS
7ML19985JJ03