b) Dimensions:Connection M14x1.5 metric
Fig. 3
Housing:
Nominal voltage:
Capacity:
Pressure:
Absorption
capacity:
Check valves:
Effectivity: 912 i Series
Edition 1/Rev. 2
BRP-Powertrain
INSTALLATION MANUAL
73mm
(2.87 in.)
157mm
(6.18 in.)
Part
1
stainless steel
12 V
approx. 120 l/h (31.7 US gal/h)
min. 4.5 bar (65.3 psi) (absolute pressure)
up to -400 mbar (-5.8 psi) compared to ambient (depending
on the vapor pressure of the fuel used)
a) opening pressure max. 70 mbar (1.02 psi)
b) resistance max. 70 mbar at 75 l/h (19.8 US gal/h)
c) pressure safe up to 20 bar (290 psi)
213.5mm (8.41in.)
1
241.8 mm (9.52 in.)
Function
Fuel pump assy.
14.5mm
(0.57 in.)
06398
73-00-00