Approval Of Electric And Electronic Components - Rotax 912 i Series Installation Manual

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

1.1)

Approval of electric and electronic components

(Equipment Qualification according to RTCA/DO-160)
RTCA/DO-160 defines a series of minimum standard environmental test
RTCA/DO-160
conditions and applicable test procedures for airborne equipment. The
purpose of these tests is to provide a laboratory means of determining the
performance characteristics of airborne equipment in environmental condi-
tions representative of those which may be encountered in airborne opera-
tion of the equipment.
Electric and Electronic components (incl. wiring harness, ECU, Fuse Box,
PMA, Sensors and Actuators) of the 912 iS / 912 iSc are deemed to be
part of the Equipment and therefore tested and qualified according to the
following table:
DO-160G, Section 4 - Temperature and Altitude
DO-160G, Section 5 - Temperature Variation
DO-160G, Section 6 - Humidity
DO-160G, Section 7 - Operational Shocks and Crash Safety Cat.B
DO-160G, Section 8 - Vibration
DO-160G, Section 9 - Explosion Proofness
DO-160G, Section 10 - Water Proofness
DO-160G, Section 11 - Fluids Susceptibility
DO-160G, Section 12 - Sand and Dust
DO-160G, Section 13 - Fungus Resistance
DO-160G, Section 14 - Salt Spray
DO-160G, Section 15 - Magnetic Effect
DO-160G, Section 16 - Power Input
DO-160G, Section 17 - Voltage Spike
DO-160G, Section 18 - AF Cond. Susceptibility
DO-160G, Section 19 - Induced Signal Susceptibility
§19.3.5 Spikes Induced Into Interconnecting Cables
DO-160G, Section 20 - RF Susceptibility
DO-160G, Section 21 - Emission RF Energy
DO-160G, Section 22 - Lightening Induced Trans. Suscept.
DO-160G, Section 23 - Lightening Direct Effects
DO-160G, Section 24 - Icing
DO-160G, Section 25 - Electrostatic Discharge
X...............Test not performed
* ...............Components were tested at „operating low temperature" of
- 25° C (- 13° F) instead of - 45° C (- 49° F) and „Altitude" of 18.000 ft
instead of 25.000 ft.
Effectivity: 912 i Series
Edition 1/Rev. 2
BRP-Powertrain
INSTALLATION MANUAL
Cat. B3V*
Cat.B
Cat.B
Cat.S
(L general, M for ECU)
X
Cat. S
Cat. F
Cat. D
X
Cat. S
Cat. A
Cat.BXX
Cat.B
Cat. Z
Cat. ZC
Cat. R
Cat.B
Cat. A3G3L3
X
X
Cat. A
24-00-00
Page 4
January 01/2014