Dimensions Of The Exhaust System; Exhaust System Assy - Rotax 912 i Series Installation Manual

Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

4) Dimensions of the exhaust system

4.1)

Exhaust system assy.

See
Location and po-
sition of the tem-
perature sensor
The axis of the temperature sensor may be inclined up to 75 ° from the
vertical, so that any residual water will not be collected in the tip of the
temperature sensor.
The sensor element itself has no particular orientation, it can be rotated
360° around the axis. The tip of the temperature sensor must be positi-
oned free in the gas flow.
Approx. 50 mm (1.97 in.) from the cylinder head flange i.e. measured
Position
from the flat surface on the cylinder head to encoder axis. It is important
that all 4 temperature sensors are placed at the same distance!
Position
Graphic
Fig. 4
Effectivity: 912 i Series
Edition 1/Rev. 2
BRP-Powertrain
INSTALLATION MANUAL
Fig. 4
und
Fig. 5.
If the EGT sensor is fitted on a slope or with the sen-
NOTICE
WARNUNG
sor tip pointing upwards, then various fluids can lead
to undesired corrosion. The sensor could then fail.
~ 50 mm/~ 1.97 in.
~ 50 mm/~ 1.97 in.
06592
78-00-00
Page 9
January 01/2014

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents