5.1.3

Monitor data 1

Function codes for monitor data 1 (M codes) are described in the four tables (1 to 4) below.
These function codes are for reading only.
These function codes are for reading only. The "Support" column of the table indicates whether
each function is supported by the respective models or not. ○ indicates the function is supported,
and × indicates the function is not supported.
Code
Name
M01
Frequency
reference (p.u.)
(Final command)
M02
Torque command
(Final command)
M03
Torque current
command
(Final command)
M04
Flux command
M05
Frequency
reference
(Final command)
M06
Output frequency 1
(p.u.)
M07
Torque real value
M08
Torque current
M09
Output frequency
M10
Input power
M11
Output current
effective value
M12
Output voltage
effective value
*1 Since M12 does not have any data after the decimal point, the minimum step is 1.0.
5.1 Communications Dedicated Function Codes
Table 5.8 Monitor data 1 function codes (1)
Description
Frequency
-32768 to 32767
command based on
(±20,000 = maximum
the maximum
frequency)
frequency
Torque command
-327.68 to 327.67
based on the motor
rated torque (100%)
Torque current
-327.68 to 327.67
command based on
the motor rated
torque current
(100%)
Flux command
-327.68 to 327.67
based on the rated
motor flux (100%)
Frequency
0.00 to 655.35
command with min.
step 0.01 Hz
Output frequency
-32768 to 32767
based on the
(±20,000 = maximum
maximum frequency
frequency)
(before slip
compensation)
Motor output torque
-327.68 to 327.67
based on the motor's
rated torque (100%)
Torque current
-327.68 to 327.67
based on the rated
torque current of the
motor (100%)
Output frequency
FGI:
with min. step 0.01
-655.35 to 655.35
Hz
RTU:
0.00 to 655.35
Power consumption
0.00 to 399.99
value based on the
"nominal applicable
motor output"
(100%)
Output current
0.00 to 399.99
effective value based
(100% = inverter
on the inverter rated
rated current)
current
Output voltage
0.0 to 1000.0
effective value
(min. step: 1.0 V)
5-11
Min.
Monitor range
step
1
0.01
0.01
0.01
0.01
1
0.01
0.01
0.01
0.01
0.01
0.1
*1
Support
Unit
HVAC/AQUA
×
%
×
%
×
%
Hz
%
×
%
Hz
%
%
V