Command Data - Fuji Electric FRENIC-AQUA series User Manual

Rs-485 communication
Hide thumbs Also See for FRENIC-AQUA series:
Table of Contents

Advertisement

5.1.2

Command data

[ 1 ] List of command data
The table below shows the function codes (S code) for the command data. The "Support"
column indicates whether the function code is supported or not. The symbol "O" means that the
code is supported and the symbol "X" means that the code is not supported.
Code
Name
S01
Frequency
reference (p.u.)
S02
Torque
command
S03
Torque current
command
S05
Frequency
reference
S06
Operation
command
S07
Universal DO
S08
Acceleration
time F07
S09
Deceleration
time F08
S10
Torque limit
level (Driving)
S11
Torque limit
level (Braking)
S12
Universal AO
S13
PID command
S14
Alarm reset
command
S19
Speed
command
Table 5.2 List of command data
Function
Frequency command
issued through
communications (the
reference value for
maximum frequency)
Torque command
issued through
communications
Torque current
command issued
through
communications
Frequency command
issued through
communications (in
units of 0.01 Hz)
Operation command
issued through
communications
[general input terminal
functions (X1 to X7, XF
(FWD), R (REV)) and
FWD, REV, RST only
through
communications]
Command issued to
DO terminal through
communications
Each data is set with
the code or
communications format
common to all the
inverter types.
Command issued to
AO terminal through
communications
PID command issued
through
communications
Alarm reset command
issued through
communications
Speed command
issued via
communications
* Legends in R/W column...R: Readable, W: Writable, R/W: Readable/writable
Permissible setting
In units
range
of
-32768 to 32767
1
(Max frequency:
at +/- 20000)
-327.68 to 327.67
0.01
-327.68 to 327.67
0.01
0.00 to 655.35
0.01
0000
to FFFF
1
H
H
0000
to FFFF
1
H
H
0.0 to 3600.0
0.1
0.0 to 3600.0
0.1
20.00 to 150.00,
0.01
999
20.00 to 150.00,
0.01
999
-32768 to 32767
1
(Full scale: at +/-
20,000)
-32768 to 32767
1
(+/- 20000
corresponds to +/-
100%)
0 or 1
1
-32768 to 32767
1
5-2
Support
Unit
R/W *
HVAC AQUA
R/W
×
×
%
R/W
×
×
%
R/W
Hz
R/W
R/W
R/W
s
R/W
s
R/W
%
R/W
%
R/W
R/W
R/W
R/W
-1
min
R/W

Advertisement