Russian; Dc (Direct Current) - Vectra Fitness Genisys 2761 User Manual

Two/four channel electrotherapy / combination system / with cart, no semg, therapy system cart assembled / unassembled, nimh battery module, dual channel semg module, user remote controls, channel 3/4 electrotherapy module
Table of Contents

Advertisement

SPECiFiCATiONS
wAvEFOrM SPECiFiCATiONS (CONTiNuEd)

Russian

Russian Current is a sinusoidal waveform, delivered in bursts or
series of pulses . This method was claimed by its author (Kots)
to produce maximal muscle strengthening effects without
significant discomfort to the patient .
Output Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electrodes
Output Intensity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 -100 mA(CC)
Carrier Frequency (Fixed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,500 Hz
Channel Mode . . . . . . . . . . . . . . . . . . . . . . . . . Single, Reciprocal, Co-Contract
Duty Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10%, 20%, 30%, 40%, 50%
Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CC or CV*
Anti-Fatigue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Off or On
Cycle Time . . . . . .Continuous, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50
Burst Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-100 bps
Ramp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 . 5 , 1, 2 and 5 sec
Treatment Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-60 min
Available on Channels . . . . . . . . . . . . . . . . . . . . . . . . 1 & 2, 3 & 4 Option
*CC= Constant Current
CV= Constant Voltage
DC Current is a direct current flowing in one direction only . The
current can be continuous or interrupted .
Output Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electrodes
Output Intensity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-4 mA
Polarity Reversal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . On or Off
0- 100 V (CV)
Cycle Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous, 5/60, 10/60
Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CC*
Treatment Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 min
Available on Channels . . . . . . . . . . . . . . . . . . . . . . . . 1 & 2, 3 & 4 Option
23

DC (Direct Current)

With Polarity Reversal On, Polarity will change at
50% of treatment time .