MEOLink User Manual
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Modem fault status.
fault status.
individual fault bit mask settings are the bit masks (2^x) of ram(0),
flash(1), fpga(2), rf(3), ps(4), temp(5)."
::= { mm1GeneralStatus
mm1AlarmStatus OBJECT-TYPE
SYNTAX
mm1BitMask
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Modem alarm status.
alarm status. A value of zero indicates there are no alarms.
individual alarm bit mask settings are the bit masks (2^x) of
calError(0), noFiltFile(1), syncLoss(2), frqRefSw(3), tempHigh(4),
bufOvfl(5), bufUnfl(6), fanSpeed(7), rldPty(8), lvdsPty(9), plAlm(10),
genDiag(11), activeDataLinkADown(12), activeDataLinkBDown(13),
fanFailed(14), noConfigFile(15)."
::= { mm1GeneralStatus
mm1CbitStatus OBJECT-TYPE
SYNTAX
INTEGER { fail(0), pass(1) }
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Modem continuous built-in test (CBIT) status."
::= { mm1GeneralStatus
mm1CpuUtilization OBJECT-TYPE
SYNTAX
INTEGER (0..100)
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"CPU percent utilization."
::= { mm1GeneralStatus
mm1LastHandoverTime OBJECT-TYPE
SYNTAX
DateAndTime
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Time of last satllite handover event (UTC)."
::= { mm1DashboardStatus
mm1HandoverStatus OBJECT-TYPE
SYNTAX
INTEGER { idle(0), inProgress(1) }
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Current handover status."
::= { mm1DashboardStatus
mm1ActiveDataEthernet OBJECT-TYPE
SYNTAX
INTEGER { secondary(0), primary(1) }
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Active Ethernet data plane."
::= { mm1DashboardStatus
Rev 002vx
1141780,
The fault mask bits are OR'd together to form the
A value of zero indicates there are no faults.
5 }
The alarm mask bits are OR'd together to form the
6 }
7 }
8 }
1 }
2 }
3 }
The