MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"The Quality of Service (QoS) queue size for the corresonding index."
::= { mm1QosQueueSizeEntry 2 }
mm1AcmEsNoReportInterval OBJECT-TYPE
SYNTAX
mm1MilliSecond (30..2000)
UNITS
"sec"
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"ACM Es/No report interval (0.03 to 2 sec; 0.5 sec default)."
::= { mm1AcmConfig
mm1AcmModCodTimeout OBJECT-TYPE
SYNTAX
mm1MilliSecond (1000..30000)
UNITS
"sec"
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"ACM Base ModCod reversion timeout (1 to 30 sec; 5 sec default).
If no Es/No report is received in this time period, modem reverts to
base ModCod."
::= { mm1AcmConfig
mm1AcmModCodMask OBJECT-TYPE
SYNTAX
Unsigned32
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"ACM ModCod mask.
form one mask value. The individual MODCOD bit mask settings are as
follows:
modCodMask1(1), modCodMask2(2), modCodMask3(4),
modCodMask4(8), modCodMask5(16), ...
The mask setting for any undesired MODCOD is 0."
::= { mm1AcmConfig
mm1AupcUpdateInterval OBJECT-TYPE
SYNTAX
mm1MilliSecond (500..60000)
UNITS
"sec"
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"AUPC update interval (0.5 to 60 sec; 2.0 sec default)."
::= { mm1AupcConfig
mm1AupcMinUtilization OBJECT-TYPE
SYNTAX
INTEGER (0..100)
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"AUPC target minimum link utilization (0 to 100 percent; 30 percent default),
AUPC will strive to keep utilization above this level."
::= { mm1AupcConfig
mm1AupcMaxUtilization OBJECT-TYPE
SYNTAX
INTEGER (0..100)
MAX-ACCESS
read-write
STATUS
current
DESCRIPTION
"AUPC target maximum link utilization (0 to 100 percent; 50 percent default),
7‐80
1 }
2 }
The 28 ModCod bit mask settings are OR'd together to
3 }
1 }
2 }
MEOLink User Manual
Rev 002vx
1141780,
Need help?