Engine Installation (Hvac) - Polaris RANGER XP 1000 2018 Service Manual

Table of Contents

Advertisement

26. Connect
the
battery.
specification.
TORQUE
Battery Terminal Fasteners:
40 in-lbs (5 Nm)

ENGINE INSTALLATION (HVAC)

1. Complete Engine Installation, page 3.24.
2. Install both coolant hoses onto the water pump. Install
q
w
clamp
and
. Torque clamp
TORQUE
Coolant hose clamp:
35 in-lbs (4 Nm)
3. Attach coolant hose to oil cooler and install clamp
9928487 R01 - 2018 RANGER XP 1000 Service Manual
© Copyright Polaris Industries Inc.
Torque
fasteners
to
4. Install orange alternator hot wire and torque fastening
w
to specification.
5. Connect both AC lines to the compressor. Torque AC
e
.
6. Reinstall the battery cover and flip down the
7. Fill coolant reservoir. Bleed system as required. See
8. Check and fill engine oil as required. See Engine Oil
9. Connect
ENGINE / COOLING / EXHAUST
nut to specification.
TORQUE
Alternator wire to Terminal Block:
3.3 ft-lbs (4 Nm)
lines to specification.
TORQUE
AC lines at compressor:
18 ft-lbs (24 Nm)
passenger seat.
Cooling System Bleeding Procedure, page 3.91.
and Filter Replacement, page 2.34.
the
battery.
Torque
specification.
3
fasteners
to
3.27