CAUTION
– Exposing or immersing the AeroDR Detector to
patient body fluids, chemicals, water, etc. may
allow such liquids to enter through exterior gaps
and cause a failure. Make sure to cover the
AeroDR Detector with a vinyl sheet, etc.
– Be careful of the ingress of patient body fluids,
chemicals, water, etc., because the AeroDR
1417HQ, AeroDR 1417S, AeroDR 1717HQ, and
AeroDR 1012HQ are not designed to be water-
proof.
– The AeroDR 2 1417HQ and AeroDR 2 1417S are
designed to have waterproof capabilities, but be
careful when handling them because they are not
guaranteed to be completely waterproof. Also,
be careful because subjecting them to strong
impacts or excessive loads by dropping or hitting
them against other objects may diminish their wa-
terproof capabilities.
– Never leave AeroDR Detectors in hot and humid
environments for long periods of time.
– The AeroDR Detector has wireless antennae po-
sitioned at 2 places. Do not block them with the
body or metal because that will interfere with, dis-
connect or slow down wireless communication.
– Pressing the power switch causes each LED
(green, orange, blue) to light temporarily or
flash. After this, only green begins to flash in a
slow cycle. Please check the lighting or flashing
of each color once.
– The battery capacity is designed to allow the life
period calculated based on the standard usage
of the AeroDR Detector. It can be replaced with
a new battery for a fee if replacement is neces-
sary after the warranty period due to battery
breakdown or decrease in capacity.
– Check that the buzzer sounds when mounted on
the AeroDR Battery Charger or AeroDR Battery
Charger2.
– Check that the LED indicates recharging status
when the AeroDR 1417HQ, AeroDR 1417S,
AeroDR 1717HQ, or AeroDR 2 1417HQ is
mounted on the AeroDR Battery Charger.
– Check that the LED indicates recharging status
when mounted on the AeroDR Battery Charger2.
– Be careful not to get your hand caught when
setting the AeroDR Detector into the AeroDR
Battery Charger or AeroDR Battery Charger2.
– If the AeroDR Detector is inserted into the
AeroDR Battery Charger or AeroDR Battery
Charger2, make sure that the AeroDR Battery
Charger or AeroDR Battery Charger2 will not tip
over due to any shock applied to the AeroDR
Detector.
– The AeroDR Detector is precision equipment,
and therefore impact or vibration during radiog-
raphy or image transfer may affect the image
quality. Be careful when handling the AeroDR
Detector during and just after radiography.