Appendix
D
Serial Commands
Serial Command Syntax
< > = Required argument. Replace appropriately.
For example:
-u <DB_User_name> becomes -u av where av replaces DB_User_name.
| = Mutually exclusive arguments. Choose one from the list.
{ } = Used with | to specify a list of choices for an argument.
[ ] = Optional parameter.
Important: Unless otherwise stated, commands will respond with !OK on success and
!ERROR on failure.
AUTOCAL [-exp={0|1}] [-expval={60-100000}] [-gain={0|1}] [-gainval
={0-100}] [-focus={0|1}] [-focval{0-9999}]
Initiates camera calibration of gain, exposure, and focus. Each parameter is independent.
Ranges are device-dependent.
CHECKSUM {BOOT | KERNEL | BOOTPARAM}
Gets a checksum on an individual part of the system.
DELETE <key>
Deletes a key.
FINDCHILDREN [-parent=clsid] [-child=symname]
Retrieves the children of type clsid for the symbolic parent.
FINDPARENT [-parent=clsid] [-child=symname]
Retrieves the first parent of type clsid for the symbolic child.
FINDSTEPS [-type=clsid]
Retreives a csv step list in symbolic form of the type passed in the current job.
GET {tagname|service|service.tagname}
Gets value of a global tag.
The tagname must correspond to one of the supported tags within the device. Use the
INFO command to get a full list of tags and services, as well as attributes of the tag and list
of subtags.
The command is terminated by a carriage return and/or line feed character.
Include an index to get a single value from an array such as GET int1. If the index is
omitted, the full array of values will be returned in a comma-separated list of values.