Technical data
10.10 Accessories
Table 10-27 Technical data of the braking resistors
Article no.
Resistance
Pulse power P
max
Rated power P
DB
Temperature contact (NC
contact)
Degree of protection
Weight
Figure 10-9
428
JJY:023464020001
5 Ω
110 kW
5500 W
250 VAC / 2.5 A
IP21
27 kg
Pulse power P
, rated power P
max
resistor
and examples of the switch-on duration of the braking
DB
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF