Overview Of How To Replace An Inverter - Siemens SINAMICS G120C USS/MB Operating Instructions Manual

Sinamics g120c series low voltage converter built-in units with frame sizes aa - f
Hide thumbs Also See for SINAMICS G120C USS/MB:
Table of Contents

Advertisement

9.2.1

Overview of how to replace an inverter

Permissible replacement
You must replace the inverter if it continually malfunctions.
In the following cases you will need to replace the inverter:
Replacement:
● Same power rating
● Same firmware version
Unexpected machine movements caused by incorrect/inappropriate inverter settings
Replacing inverters of different types can result in incomplete or incorrect/inappropriate
inverter settings. As a consequence, unexpected machine motion, e.g. speed oscillation,
overspeed or incorrect direction of rotation. Unexpected machine motion can result in death,
injury or material damage.
● In all cases that are not permitted according to the table above, recommission the drive
Special issue relating to communication via PROFINET: Device replacement without removable data
storage medium
The inverter supports the PROFINET functionality, replacing the device without data storage
medium.
Requirement
The topology of the PROFINET IO system with the IO device involved is configured in your
higher-level control system.
SINAMICS G120C converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF
Replacement:
● Same power rating
Higher firmware version
(e.g. replace FW V4.2 by
FW V4.3)
WARNING
after replacing an inverter.
9.2 Replacing inverter components
Replacement:
● Same frame size
Higher power rating
● Same firmware version
Inverter and motor must match one another (ratio between
the motor and inverter rated power > 1/4)
Corrective maintenance
Replacement:
● Same frame size
Higher power rating
Higher firmware version
(e.g. replace FW V4.2 by
FW V4.3)
371

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120c dpSinamics g120c pn

Table of Contents