IMPORTANT!
Maintenance procedures
1. Pumps
Check pumps for watertightness, pump rotor noise, rotation
direction and function
Check pump suction
Check pump sieves correctly fitting and operating correctly
Check sliding ring washer/contra-rotation ring
2. Wash systems
Check water level in tank
Check that wash water pipe is watertight
Check washing system is complete and produces correct spray
pattern
Check wash arm hubs
3. Fresh water rinse
Check flow pressure/water pressure
Check rinsing system is complete and produces correct spray
pattern
Check that system is watertight
4. Housing and mounting parts
Check housing, tank, sheet metal cover, hood, doors and
covering of machine base for damage and correct operation
Check tank cover sieves
Check boiler, hoses, clamps, plastic parts and seals
Check operation of raising and lowering equipment
5. Fresh water installation
Check level regulation
Check valves, clean dirt trap
Datei:1_FV40_60-2_9546822_Betriebsanleitung_EN_2004-03.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
17.1.2 Observe the environmental protection regulations
Legal obligations relating to the avoidance of waste materials and to their
recycling/removal in accordance with applicable regulations must be observed!
In particular, during installation, repair and maintenance work, materials that could
pollute water such as: Grease and oils, Cleaning fluids containing solvents, must not
pollute the ground or run into the sewerage system! These materials must be stored,
shipped, collected and disposed of in suitable containers!

17.2 Dosing units

The dosing units themselves are maintenance free in principle but the working life is
largely dependent on the chemical used.
17.2.1 Change of products
Change of product means that one rinse aid or detergent product is replaced by another.
The use of differing products alongside each other can result in break-downs.
Hose lines and dosing units must always be rinsed out with warm water.

17.3 Maintenance plan

Update: 2008-03-10
W e reserve the right to change execution and construction!
S. „FV 40 G"
39/42