Assignment List View Inputs / Control Outputs - Meiko FV 40.2 Operating Instructions Manual

Dish- and glasswashing machine
Table of Contents

Advertisement

Operating instructions FV 40.2 / FV 40.2 G / FV 60.2
15.5
Assignment list
View inputs / control outputs
Indication
Left
Right
In
1
0/1
In
2
0/1
In
3
0/1
In
4
0/1
In
5
0/1
In
6
0/1
In
7
0/1
In
8
0/1
In
9
0/1
In
10
0/1
In
12
0/1
In
13
0/1
In
14
0/1
In
15
0/1
In
16
0/1
In
17 0 .. 255
In
18 0 .. 255
In
19
xxx
In
20
xxx
In
21
xxx
In
22 0 .. 255
In7
9
0/1
In7
10
0/1
In7
18
0/1
In7
19
0/1
Ou
1
0/1
Ou
2
0/1
Ou
3
0/1
Ou
4
0/1
Ou
5
0/1
Ou
6
0/1
Ou
7
0/1
Ou
8
0/1
Ou
9
0/1
Ou
10
0/1
Ou
11
0/1
Ou
12
0/1
Ou7
4
0/1
Ou7
5
0/1
Ou7
6
0/1
Ou7
8
0/1
Ou7
9
0/1
Datei:1_FV40_60-2_9546822_Betriebsanleitung_EN_2004-03.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
Input / output / other
Door closed
Boiler level
Leak water switch floor
not occupied
not occupied
not occupied
Hall-sensor ADT (vacuum dosing)
not occupied
not occupied
not occupied
not occupied
Threshold tank level. 1
Threshold tank level. 2
Threshold tank level. 3
Tank level. 4 (Option)
Without function
Without function
Boiler temperature in °C or °F
Tank temperature in °C or °F
Tank level (1 mm unit)
Without function
Level switch in water softener inlet chamber
"No salt" switch
not occupied
not occupied
Wash pump
Booster Pump
Drain pump
Rinse aid – dosage pump
Detergent – dosage pump / valve from ADT
Operation indicator
Filling valve
SASm soft starter system
Boiler heating
Tank heating
not occupied
not occupied
Booster pump water softener
not occupied
not occupied
Solenoid valve Y2 EW
Solenoid valve Y3 EW
Update: 2008-03-10
W e reserve the right to change execution and construction!
S. „FV 40 G"
Conditions
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
none
No leak water
No leak water
No leak water
No leak water
No leak water
No leak water
No leak water
No leak water
No leak water
No leak water
none
none
No leak water
none
none
No leak water
No leak water
33/42