Advertisement

Operating instructions
Model FV 40.2
General information and safety information
1_FV40-2_9526745_Allgemein_EN_2001-10

Advertisement

Table of Contents
loading

Summary of Contents for Meiko FV 40.2

  • Page 1 Operating instructions Model FV 40.2 General information and safety information 1_FV40-2_9526745_Allgemein_EN_2001-10...
  • Page 2 Contents Operating instructions FV 40.2 Contents Contents Declaration of conformity and other certificates General safety information Basic information on the small machine Documentation Appendix Declaration of conformity and other certificates See separate EU-declaration of conformity. General safety information This model has been exclusively designed for the washing of dishes, cutlery and glasses.
  • Page 3 General safety information Operating instructions FV 40.2 Danger of burning: indicates possible hazard due to hot surfaces or media. Danger of crushing: indicates hazard caused by moving parts of the appliance. Note: includes important additional information for the operator regarding the system or parts of the system and offers further information.
  • Page 4 General safety information Operating instructions FV 40.2 Ø Mains supply without neutral (N): for connection to three-phase current use a supply connection terminal strip with 4 poles (L1, L2, L3, PE) and, in the case of alternating current, use a supply connection terminal strip with 3 poles (L1, L2, PE) Ø...
  • Page 5 General safety information Operating instructions FV 40.2 Open the door very carefully during the program cycle, as otherwise wash water could splash out. 3.3.1 Emergency switch Ø Set the local main switch to ”OFF“ or disconnect the local main fuse.
  • Page 6 General safety information Operating instructions FV 40.2 Ø Therefore, set the local main switch to ”OFF“ or disconnect the local main fuse. The appliance can now be properly recycled (stainless steel, plastic materials, etc. separately). Basic information on the small machine Each machine is manufactured according to state of the art technology.
  • Page 7 Basic small machine information Operating instructions FV 40.2 4.1.4 Rinse aid dosing Liquid rinse aid is added into the final rinse system by an integrated dosing unit. The exact dosing of the rinse aid is guaranteed by a time switch The instructions for operating and adjustment of the dosing units can be found in the ”Service Instructions“.
  • Page 8 The Service Instructions are part of the Operating Instructions and should be kept in the appliance together with the wiring diagram. Appendix Name and address of manufacturer MEIKO Maschinenbau GmbH & Co. KG Englerstrasse 3 D-77652 Offenburg Phone: (++ 49) 781 / 203 - 0 Fax: (++ 49) 781 / 203 - 1121 www.meiko.de...
  • Page 9 Operating instructions Model FV 40.2 Operating instructions 1_FV40-2_9526746_Bedienung_EN_2001-10 Update: 2005-11-24...
  • Page 10: Table Of Contents

    Contents Operating instructions FV 40.2 Contents Contents Operation Shutting the machine down Care and Maintenance Machine with built-in AktivClean water softening device. Troubleshooting Appendix Operation The appliance must not be used without a thorough knowledge of the "General Information and Safety Information". Incorrect operation could result in injuries to personnel or damage to the appliance.
  • Page 11: Operation

    Operation Operating instructions FV 40.2 Key / display Meaning Short cycle for lightly soiled items Normal cycle Intensive cycle Wash temperature Final rinse temperature Programme start Tank drain Self-cleaning cycle Switch off appliance / Cycle interruption Table 1; Program key function / items to be washed...
  • Page 12: Shutting The Machine Down

    Operation Operating instructions FV 40.2 Operation during washing and rinsing cycle The relevant lights indicate when the appliance is ready for operation. (see also illustrations in chapter 2.1) The following fundamental principles must be observed when placing the items to be washed in the baskets: All hollow containers must always to be loaded upside down.
  • Page 13: Care And Maintenance

    Care and Maintenance Operating instructions FV 40.2 Care and Maintenance Care, general The appliance has been designed to minimise the need for cleaning, care and maintenance. However, correct care and maintenance is necessary for reliable, safe and long-lasting operation of the appliance and in the interest of hygiene and cleanliness.
  • Page 14: Machine With Built-In Aktivclean Water Softening Device

    Care and Maintenance Operating instructions FV 40.2 The cleanliness of final rinse nozzles must be checked weekly and if necessary clean under running water. The inserts for final rinse nozzles must be inserted with the prongs facing the direction of the water flow.
  • Page 15 Appliance with AktivClean built-in water softening Operating instructions device FV 40.2 Capacity of the built-in water softening device between two regenerations Hardness (°Gh) Capacity (I) Regeneration The automatic regeneration is indicated by a yellow light. The regeneration lasts approx 8 minutes.
  • Page 16: Troubleshooting

    Appliance with AktivClean built-in water softening Operating instructions device FV 40.2 Red light is flashing: The water softening device is exhausted and supplies only hard water. Re-fill with salt You should be aware that the consequence of continuing to use the appliance with an exhausted water softening device could be loss of capacity or the machine could even become unserviceable.
  • Page 17 Troubleshooting Operating instructions FV 40.2 Flashing On Illustration 3; Example of lights Except in the case of the fault "Error at the memory module", the operation of the machine can, in principle, continue after a fault has been indicated. To continue, remedy the fault according to the table below and acknowledge the error message by pressing the confirmation key.
  • Page 18: Appendix

    The appliance and the suction pipe must therefore be flushed out. Inform the service engineer. Appendix Name and address of manufacturer MEIKO Maschinenbau GmbH & Co. KG Englerstrasse 3 D-77652 Offenburg Phone: (++ 49) 781 / 203 - 0 Fax: (++ 49) 781 / 203 - 1121 www.meiko.de...
  • Page 19 Operating instructions FV 40.2 Service instructions 1_FV40-2_9526747_Service_EN_2001-10...
  • Page 20: Safety Information

    Contents Operating instructions FV 40.2 Contents Contents Authorized user of this documentation Safety information Transport, delivery, dimensions Installation, commissioning Maintenance Appliance with built-in AktivClean water softener Appendix Authorized user of this documentation The work described in this booklet may only be carried out by specialists of the manufacturer, the responsible agency or an authorized dealer.
  • Page 21: Transport, Delivery, Dimensions

    Small quantities of steam may escape from the door of the appliance. Furniture and equipment situated near the door must be protected. An engineer from your local MEIKO Service Centre can install the appliance at the required position and connect the tables - upon request.
  • Page 22 Installation, initial operation Operating instructions FV 40.2 Installation 5.2.1 Electrical connections The conditions to be provided by the customer for the electrical connection of the appliance can be found in the chapter ”Requirements for Electrical Connection“ in the ”General Information and Safety Information“ section of the Operating Instructions.
  • Page 23 Installation, initial operation Operating instructions FV 40.2 Dosing units 5.3.1 General information The appliance is provided with detergent and rinse aid units as standard. Only lather-free detergents and rinse aids suitable for industrial mechanical dishwashers may be used. If unsuitable products are used, the life expectancy of the dosing units can be reduced considerably.
  • Page 24 Installation, initial operation Operating instructions FV 40.2 5.3.3 Rinse aid dosing unit Type PG-0,4 SIL The rinse aid dosing unit is designed to automatically add liquid final rinse aid into the fresh water. The rinse aid is moved from the container into the fresh water supply line by means of a hose line.
  • Page 25: Maintenance

    Installation, initial operation Operating instructions FV 40.2 Stage 0,00 0,00 ­ ¡ ¡ ¡ ¡ ¡ 0,36 0,03 ­ l ¡ ¡ ¡ ¡ 0,71 0,06 ­ l l ¡ ¡ ¡ 1,07 0,10 ­ l l l ¡ ¡...
  • Page 26: Appliance With Built-In Aktivclean Water Softener

    Regeneration runs automatically, and the regeneration counter is re-set to 0. Appendix Name and address of manufacturer MEIKO Maschinenbau GmbH & Co. KG Englerstrasse 3 D-77652 Offenburg Phone no.: (++ 49) 781 / 203 - 0 Fax no.: (++ 49) 781 / 203 - 1121...
  • Page 27: Water Softener

    SHORT OPERATING INSTRUCTIONS FV 40.2 Control panel Preparing to wash and rinse Ø Open the door. Ø Insert wash water strainers. Ø Close the door. Ø Turn on the machine by pressing one of the pre-selector buttons. Ø Check level and if necessary refill detergent and rinse aid reservoirs.
  • Page 28 Anschlußvorschrift für Laugenpumpe Connection prescription for drain pump Prescription de connexion pour pompe de vidange 8.97/LP 5-sprachig.DOC Prescrizioni di collegamento per la pompa scarico Prescripciones para la conexión de la bomba de vaciado Druckleitung, durchgehend steigend verlegt Freier Auslauf Pressure pipe continuously ascending Air gap Tuyau de pression continuellement ascendant Système anti-refoulement avec...
  • Page 31: Service Procedures

    Service plan for stationary rack machines Service procedures 1. Pumps Check pumps for watertightness, pump rotor noise, rotation direction and function Check pump suction Check pump sieves correctly fitting and operating correctly Check sliding ring washer/contra-rotation ring 2. Washing systems Check water level in tank Check that wash water pipe is watertight Check washing system is complete and produces correct...
  • Page 32 Service plan for stationary rack machines Service procedures 7. Electrical installation Check of all fuses Tighten all electrical connections Check tank and boiler heating Check thermostat and stop switch 8. Detergent dosage Check dosage, adjust if necessary 9. Rinsing dosage Check dosage, adjust if necessary 10.
  • Page 33 Saugleitung für Reiniger bzw. Klarspüler Suction line for detergent resp. rinse aid Conduite d'aspiration pour détergent, resp. produit tensio-actif Tubo d´aspirazione per detergente e brillantante Tubo de aspiración para detergente y abrillantador Układ ssący płynu do mycia lub nabłyszczacza Aanzuigleiding voor zeep- resp. naglansmiddel 9 006 926 Klarsichtschlauch für Reiniger Transparent hose for detergent...
  • Page 34 Dr. Thomas Peukert Leiter Entwicklung und Konstruktion Postanschrift / Postal Address / Adresse postale: MEIKO Maschinenbau GmbH & Co. KG – Englerstr. 3 – D-77652 Offenburg – Postfach 2040 – D-77610 Offenburg Telefon: +49 781 203-0 MEIKO Maschinenbau GmbH & Co. KG – Offenburg – HRA Offenburg 603...

Table of Contents