Water Separator

The water separator removes water from the fuel sup-
ply as the engine runs. It collects the water in a bowl
equipped with a drain valve. Drain the bowl daily to
maintain proper function.
To drain the water separator:
1. Twist the drain valve (D) located at the bottom of
the water separator counter clockwise (when
viewed from the bottom) to allow the collected
water to drain. (fig. 11-34)
2. Once all of the water in the bowl has been drained,
twist the drain valve clockwise to close it.

Fuse Panel

The electrical system in the PT-100 Forestry is
equipped with fuses that protect the electrical compo-
nents from damage. They are located in the fuse panel
on the right side of the engine compartment.(fig. 11-35)
In the event of an electrical malfunction, the most logi-
cal place to start is at the fuse panel. Check the fuse
related to the problem you are having and inspect it. If
the fuse appears black and burned, it needs to be
replaced. Replace fuses with the correct amperage
replacement fuse only. Replacing a fuse with one of a
lower amperage rating may lead to premature fuse fail-
ure. Replacing a fuse with one of a higher amperage
rating may burn out the electrical component the fuse
was meant to protect. See the troubleshooting section
in this manual for an additional resource to aid in track-
ing suspected electrical problems.