Tandem Pump Installation; Hydraulic Reservoir Clean Out - Terex PT100 Forestry Service & Repair Manual

Compact track loaders
Hide thumbs Also See for PT100 Forestry:
Table of Contents

Advertisement

Tandem Pump Installation

Figure 9-13
Figure 9-14
1. Install the mounting bolts (with spring lock washer
and flat washer) on the tandem pump, at 85 ft.-lb
(115 Nm) with blue loc-tite. (fig. 9-13, 9-14)
2. Install the hoses and tubes on the tandem pump.
3. Add manufacturer-approved hydraulic fluid.
9. Transmission and Drive Disassembly and Assembly
Install
Bolt
9-5
Hydraulic Reservoir Cleaning
The tools required for hydraulic reservoir cleaning
are listed in Table 9-3. Use manufacturer-
recommended tools whenever possible.
Table 9-3
Tool Name
Combination Wrench
Hot oil can cause personal injury. Make sure the
oil is cool before removing any components or lines.
Remove the oil filler cap only when the engine is
stopped and the machine has been allowed to cool
thoroughly
Collect and contain liquids in a suitable contain-
er. Dispose of all liquids according to local regula-
tions and mandates.
.
1. Raise the lift arms and cab according to Tilt-Up
Canopy procedure on page 11-5 of this manual.
2. Relieve hydraulic pressure from the auxiliary
circuit.
3. Drain the hydraulic fluid. Refer to Chapter 11.
Hydraulic Fluid and Filter Change.
Figure 9-15
4. Remove the (8) bolts that secure the tank
access cover. (fig. 9-15)
Compact Track Loader

Advertisement

Table of Contents
loading