List Of Special Relays/Special Registers - Mitsubishi Electric MELSEC iQ-F FX5 User Manual

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

List of special relays/special registers

The list of special relays/special registers used in pulse width measurement is shown below.
R/W: Read or write (Note, however, that only writing is allowed for the HCMOV/DHCMOV instruction.)
R: Read only
Special relays/
Function
special
registers
SM5020
CH1 pulse width measurement
status flag
SM5021
CH2 pulse width measurement
status flag
SM5022
CH3 pulse width measurement
status flag
SM5023
CH4 pulse width measurement
status flag
SM5024
CH5 pulse width measurement
status flag
SM5025
CH6 pulse width measurement
status flag
SM5026
CH7 pulse width measurement
status flag
SM5027
CH8 pulse width measurement
status flag
SM5028
CH9 pulse width measurement
status flag
SM5029
CH10 pulse width measurement
status flag
SM5030
CH11 pulse width measurement
status flag
SM5031
CH12 pulse width measurement
status flag
SM5036
CH1 period measurement complete
SM5037
CH2 period measurement complete
SM5038
CH3 period measurement complete
SM5039
CH4 period measurement complete
SM5040
CH5 period measurement complete
SM5041
CH6 period measurement complete
SM5042
CH7 period measurement complete
SM5043
CH8 period measurement complete
SM5044
CH9 period measurement complete
SM5045
CH10 period measurement complete
SM5046
CH11 period measurement complete
SM5047
CH12 period measurement complete
Description
The measurement in progress/measurement stopped status of
pulse width measurement on the target channel can be checked
by these flags.
OFF: Measurement stopped
ON: Measurement in progress
These flags turn ON at the end of the 1st period measurement on
the target channel. (They remain ON during measurement in the
always measurement mode.)
Default
OFF
OFF
19 HIGH-SPEED INPUT/OUTPUT FUNCTION
19.3 Pulse Width Measurement Function
R/W
19
R
R
195