Trigger setting
Use the event execution type detail setting.
Navigation window  [Parameter]  [FX5UCPU]  [CPU Parameter]  "Program Setting"
Operating procedure
"Program Setting" window
"Detailed Setting" window
"Event Execution Type Detailed Setting" window
Displayed items
Item
Description
Interruption Occurrence
Sets the interrupt pointer used as the trigger.
ON of Bit Data (TRUE)
Sets the device used as the trigger.
Passing Time
Sets the elapsed time.
When "Clear Output and Current Value of Timer" is enabled together with "ON of Bit Data (TRUE)" or
"Passing Time", the current values of the output (Y) and timer (T) of this program can be cleared at the first
execution turn of this program that comes after the trigger turns OFF.
1.
Click "Detailed Setting" on the Program Setting.
2.
Select the program name and set the execution type to
"Event".
3.
Click "Detailed Setting Information".
4.
Set the trigger type to execute the event execution type
program.
Setting range
I0 to I23, I50 to I177
Page 26 Bit data ON (TRUE)
• When "ms" is selected: 1 to
65535 ms (in 1 ms units)
• When "s" is selected: 1 to
65535 s (in 1 s units)
1.4 Execution Type of Program
Default
1 PROGRAM EXECUTION
1
27