Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 260

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

No.
Name
SM4988
High-speed comparison table operation (high-speed pulse
input/output module second module)
SM4990
High-speed comparison table error occurrence (high-
speed pulse input/output module second module)
SM4992
High-speed comparison table operation (high-speed pulse
input/output module third module)
SM4994
High-speed comparison table error occurrence (high-
speed pulse input/output module third module)
SM4996
High-speed comparison table operation (high-speed pulse
input/output module fourth module)
SM4998
High-speed comparison table error occurrence (high-
speed pulse input/output module fourth module)
SM5000
Multi-point output high-speed comparison table operation
SM5001
Multi-point output high-speed comparison table
completion
SM5020
Pulse width measurement operation (CH1)
SM5021
Pulse width measurement operation (CH2)
SM5022
Pulse width measurement operation (CH3)
SM5023
Pulse width measurement operation (CH4)
SM5024
Pulse width measurement operation (CH5)
SM5025
Pulse width measurement operation (CH6)
SM5026
Pulse width measurement operation (CH7)
SM5027
Pulse width measurement operation (CH8)
SM5028
Pulse width measurement operation (CH9)
SM5029
Pulse width measurement operation (CH10)
SM5030
Pulse width measurement operation (CH11)
SM5031
Pulse width measurement operation (CH12)
SM5036
Pulse width measurement period measurement complete
(CH1)
SM5037
Pulse width measurement period measurement complete
(CH2)
SM5038
Pulse width measurement period measurement complete
(CH3)
SM5039
Pulse width measurement period measurement complete
(CH4)
SM5040
Pulse width measurement period measurement complete
(CH5)
SM5041
Pulse width measurement period measurement complete
(CH6)
SM5042
Pulse width measurement period measurement complete
(CH7)
SM5043
Pulse width measurement period measurement complete
(CH8)
SM5044
Pulse width measurement period measurement complete
(CH9)
SM5045
Pulse width measurement period measurement complete
(CH10)
APPENDIX
258
Appendix 1 Special Relay List
Description
OFF: Stopped
ON: Operation
OFF: No error
ON: Error
OFF: Stopped
ON: Operation
OFF: No error
ON: Error
OFF: Stopped
ON: Operation
OFF: No error
ON: Error
OFF: Stopped
ON: Operation
OFF: Not completed
ON: Completion
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Stopped
ON: Operation
OFF: Cycle measurement not completed
ON: Cycle measurement completion
OFF: Cycle measurement not completed
ON: Cycle measurement completion
OFF: Cycle measurement not completed
ON: Cycle measurement completion
OFF: Cycle measurement not completed
ON: Cycle measurement completion
OFF: Cycle measurement not completed
ON: Cycle measurement completion
OFF: Cycle measurement not completed
ON: Cycle measurement completion
OFF: Cycle measurement not completed
ON: Cycle measurement completion
OFF: Cycle measurement not completed
ON: Cycle measurement completion
OFF: Cycle measurement not completed
ON: Cycle measurement completion
OFF: Cycle measurement not completed
ON: Cycle measurement completion
R/W
R
R/W
R
R/W
R
R/W
R
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R

Advertisement

Table of Contents
loading

Table of Contents