Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 267

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

No.
Name
SM5686
Positioning reverse rotation limit (axis 11)
SM5687
Positioning reverse rotation limit (axis 12)
SM5772
Positioning rotational direction (axis 1)
SM5773
Positioning rotational direction (axis 2)
SM5774
Positioning rotational direction (axis 3)
SM5775
Positioning rotational direction (axis 4)
SM5776
Positioning rotational direction (axis 5)
SM5777
Positioning rotational direction (axis 6)
SM5778
Positioning rotational direction (axis 7)
SM5779
Positioning rotational direction (axis 8)
SM5780
Positioning rotational direction (axis 9)
SM5781
Positioning rotational direction (axis 10)
SM5782
Positioning rotational direction (axis 11)
SM5783
Positioning rotational direction (axis 12)
SM5804
Positioning zero return direction (axis 1)
SM5805
Positioning zero return direction (axis 2)
SM5806
Positioning zero return direction (axis 3)
SM5807
Positioning zero return direction (axis 4)
SM5808
Positioning zero return direction (axis 5)
SM5809
Positioning zero return direction (axis 6)
SM5810
Positioning zero return direction (axis 7)
SM5811
Positioning zero return direction (axis 8)
SM5812
Positioning zero return direction (axis 9)
SM5813
Positioning zero return direction (axis 10)
SM5814
Positioning zero return direction (axis 11)
SM5815
Positioning zero return direction (axis 12)
SM5820
Positioning clear signal function (axis 1)
SM5821
Positioning clear signal function (axis 2)
SM5822
Positioning clear signal function (axis 3)
SM5823
Positioning clear signal function (axis 4)
Description
OFF: Reverse rotation limit OFF
ON: Reverse rotation limit ON
OFF: Reverse rotation limit OFF
ON: Reverse rotation limit ON
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Forward rotation (Current address increases)
ON: Reverse rotation (Current address increases)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Zero return start (Reverse rotation direction)
ON: Zero return start (Forward rotation direction)
OFF: Clear signal disabled
ON: Clear signal enabled
OFF: Clear signal disabled
ON: Clear signal enabled
OFF: Clear signal disabled
ON: Clear signal enabled
OFF: Clear signal disabled
ON: Clear signal enabled
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
APPENDIX
Appendix 1 Special Relay List
A
265

Advertisement

Table of Contents
loading

Table of Contents