Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 224

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

Special relays/
Function
special
registers
SD5303, SD5302
CH1 pulse width
SD5305, SD5304
CH1 period
SD5307, SD5306
CH1 Number of output pulses
current value monitor
SD5317, SD5316
CH2 number of output pulses
SD5319, SD5318
CH2 pulse width
SD5321, SD5320
CH2 period
SD5323, SD5322
CH2 Number of output pulses
current value monitor
SD5333, SD5332
CH3 number of output pulses
SD5335, SD5334
CH3 pulse width
SD5337, SD5336
Ch3 period
SD5339, SD5338
CH3 Number of output pulses
current value monitor
SD5349, SD5348
CH4 number of output pulses
SD5351, SD5350
CH4 pulse width
SD5353, SD5352
CH4 period
SD5355, SD5354
CH4 Number of output pulses
current value monitor
SD5365, SD5364
CH5 number of output pulses
SD5367, SD5366
CH5 pulse width
SD5369, SD5368
CH5 period
SD5381, SD5380
CH6 number of output pulses
SD5383, SD5382
CH6 pulse width
SD5385, SD5384
CH6 period
SD5397, SD5396
CH7 number of output pulses
SD5399, SD5398
CH7 pulse width
SD5401, SD5400
CH7 period
SD5413, SD5412
CH8 number of output pulses
SD5415, SD5414
CH8 pulse width
SD5417, SD5416
CH8 period
SD5429, SD5428
CH9 number of output pulses
SD5431, SD5430
CH9 pulse width
SD5433, SD5432
CH9 period
SD5445, SD5444
CH10 number of output pulses
SD5447, SD5446
CH10 pulse width
SD5449, SD5448
CH10 period
SD5461, SD5460
CH11 number of output pulses
SD5463, SD5462
CH11 pulse width
SD5465, SD5464
CH11 period
SD5477, SD5476
CH12 number of output pulses
SD5479, SD5478
CH12 pulse width
SD5481, SD5480
CH12 period
19 HIGH-SPEED INPUT/OUTPUT FUNCTION
222
19.7 PWM Function
Description
The pulse width is stored.
The period is stored.
The current value of the number of output pulses is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The current value of the number of output pulses is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The current value of the number of output pulses is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The current value of the number of output pulses is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
The number of pulses to output are stored.
The pulse width is stored.
The period is stored.
Default
R/W
0
R/W
0
R/W
0
R
0
R/W
0
R/W
0
R/W
0
R
0
R/W
0
R/W
0
R/W
0
R
0
R/W
0
R/W
0
R/W
0
R
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W

Advertisement

Table of Contents
loading

Table of Contents