Error
Error name
Error details and cause
code
3635H
Axis 5 positioning
• The 32-bit range was exceeded when
address error
the unit of the positioning address was
converted.
• The 32-bit range was exceeded when
the unit of the zero-point address was
converted.
• The total transfer distance before and
after the interrupt of the DVIT/DDVIT
instruction or 1-speed positioning with
interruption exceeded 7FFFFFFFH. Or,
when the operation was started, the
positioning address was set to 0.
• Pulses of 7FFFFFFFH or greater are
needed to specify an absolute address.
3636H
Axis 6 positioning
• The 32-bit range was exceeded when
address error
the unit of the positioning address was
converted.
• The 32-bit range was exceeded when
the unit of the zero-point address was
converted.
• The total transfer distance before and
after the interrupt of the DVIT/DDVIT
instruction or 1-speed positioning with
interruption exceeded 7FFFFFFFH. Or,
when the operation was started, the
positioning address was set to 0.
• Pulses of 7FFFFFFFH or greater are
needed to specify an absolute address.
3637H
Axis7 positioning
• The 32-bit range was exceeded when
address error
the unit of the positioning address was
converted.
• The 32-bit range was exceeded when
the unit of the zero-point address was
converted.
• The total transfer distance before and
after the interrupt of the DVIT/DDVIT
instruction or 1-speed positioning with
interruption exceeded 7FFFFFFFH. Or,
when the operation was started, the
positioning address was set to 0.
• Pulses of 7FFFFFFFH or greater are
needed to specify an absolute address.
3638H
Axis 8 positioning
• The 32-bit range was exceeded when
address error
the unit of the positioning address was
converted.
• The 32-bit range was exceeded when
the unit of the zero-point address was
converted.
• The total transfer distance before and
after the interrupt of the DVIT/DDVIT
instruction or 1-speed positioning with
interruption exceeded 7FFFFFFFH. Or,
when the operation was started, the
positioning address was set to 0.
• Pulses of 7FFFFFFFH or greater are
needed to specify an absolute address.
Action
• Start the positioning within specifications.
• Start the positioning within specifications.
• Start the positioning within specifications.
• Start the positioning within specifications.
Detailed
Diagnostic
information
timing
Error location
At END
information
instruction
and system
execution, at
configuration
interrupt
information
occurrence
Error location
At END
information
instruction
and system
execution, at
configuration
interrupt
information
occurrence
Error location
At END
information
instruction
and system
execution, at
configuration
interrupt
information
occurrence
Error location
At END
information
instruction
and system
execution, at
configuration
interrupt
information
occurrence
APPENDIX
335
Appendix 3 Error Code