No.
Name
SD5060
Pulse width measurement rising ring counter value [Low-
order] (CH3)
SD5061
Pulse width measurement rising ring counter value [High-
order] (CH3)
SD5062
Pulse width measurement falling ring counter value [Low-
order] (CH3)
SD5063
Pulse width measurement falling ring counter value [High-
order] (CH3)
SD5064
Pulse width measurement latest value [Low-order] (CH3)
SD5065
Pulse width measurement latest value [High-order] (CH3)
SD5066
Pulse width measurement maximum value [Low-order]
(CH3)
SD5067
Pulse width measurement maximum value [High-order]
(CH3)
SD5068
Pulse width measurement minimum value [Low-order]
(CH3)
SD5069
Pulse width measurement minimum value [High-order]
(CH3)
SD5070
Pulse width measurement cycle latest value [Low-order]
(CH3)
SD5071
Pulse width measurement cycle latest value [High-order]
(CH3)
SD5072
Pulse width measurement cycle maximum value [Low-
order] (CH3)
SD5073
Pulse width measurement cycle maximum value [High-
order] (CH3)
SD5074
Pulse width measurement cycle minimum value [Low-
order] (CH3)
SD5075
Pulse width measurement cycle minimum value [High-
order] (CH3)
SD5080
Pulse width measurement rising ring counter value [Low-
order] (CH4)
SD5081
Pulse width measurement rising ring counter value [High-
order] (CH4)
SD5082
Pulse width measurement falling ring counter value [Low-
order] (CH4)
SD5083
Pulse width measurement falling ring counter value [High-
order] (CH4)
SD5084
Pulse width measurement latest value [Low-order] (CH4)
SD5085
Pulse width measurement latest value [High-order] (CH4)
SD5086
Pulse width measurement maximum value [Low-order]
(CH4)
SD5087
Pulse width measurement maximum value [High-order]
(CH4)
SD5088
Pulse width measurement minimum value [Low-order]
(CH4)
SD5089
Pulse width measurement minimum value [High-order]
(CH4)
SD5090
Pulse width measurement cycle latest value [Low-order]
(CH4)
SD5091
Pulse width measurement cycle latest value [High-order]
(CH4)
SD5092
Pulse width measurement cycle maximum value [Low-
order] (CH4)
SD5093
Pulse width measurement cycle maximum value [High-
order] (CH4)
SD5094
Pulse width measurement cycle minimum value [Low-
order] (CH4)
SD5095
Pulse width measurement cycle minimum value [High-
order] (CH4)
APPENDIX
290
Appendix 2 Special Register List
Description
This register stores the pulse width measurement rising ring
counter value (CH3).
This register stores the pulse width measurement falling ring
counter value (CH3).
This register stores the pulse width measurement latest value
(CH3).
This register stores the pulse width measurement maximum
value (CH3).
This register stores the pulse width measurement minimum value
(CH3).
This register stores the pulse width measurement cycle latest
value (CH3).
This register stores the pulse width measurement cycle maximum
value (CH3).
This register stores the pulse width measurement cycle minimum
value (CH3).
This register stores the pulse width measurement rising ring
counter value (CH4).
This register stores the pulse width measurement falling ring
counter value (CH4).
This register stores the pulse width measurement latest value
(CH4).
This register stores the pulse width measurement maximum
value (CH4).
This register stores the pulse width measurement minimum value
(CH4).
This register stores the pulse width measurement cycle latest
value (CH4).
This register stores the pulse width measurement cycle maximum
value (CH4).
This register stores the pulse width measurement cycle minimum
value (CH4).
R/W
R
R
R
R/W
R/W
R
R/W
R/W
R
R
R
R/W
R/W
R
R/W
R/W

Advertisement

Table of Contents
loading

Table of Contents