HIGH-SPEED INPUT/OUTPUT FUNCTION
The high-speed input/output function is explained below.
Each respective function is set by parameters in GX Works3.
Function

High-speed counter function

FX3-compatible high-speed counter function
Pulse width measurement function
Pulse catch function
General-purpose input functions
PWM function
Positioning function
19.1
High-speed Counter Function
High-speed counter function is explained below.

High-speed counter function overview

The high-speed counter is a function that counts the number of high-speed pulse inputs that cannot be counted by a
conventional counter, using the general purpose input terminal of the CPU module or high-speed pulse input/output module.
Depending on the input (module) to be used, each function of the high-speed counter is limited as follows:
Input type
CPU module
High-speed pulse input/
output module
: Supported, : Not supported
The high-speed counter assigns input and function settings by parameters and operates using the HIOEN/DHIOEN
instruction.
Parameter setting and the HIOEN/DHIOEN instruction are always required to use the high-speed counter.
High-speed counter parameter setting
High-speed counter channels (input allocation, function) and high-speed counter comparison table, etc., are set by
parameters. (Page 125 High-speed counter parameters)
High-speed counter operation mode
The three high-speed counter operation modes are as follows.
Operation mode is set by parameter. (Page 125 High-speed counter parameters)
■Normal mode
Select normal mode if you want to use as an ordinary high-speed counter. (Page 126 High-speed counter (normal mode))
19 HIGH-SPEED INPUT/OUTPUT FUNCTION
114
19.1 High-speed Counter Function
Normal mode
Pulse density measurement mode
Rotational speed measurement mode
Pulse catch function
FX3-compatible pulse catch function
High-speed counter operation mode
Normal mode
Pulse density
measurement mode
Reference
Page 126
Page 129
Page 132
Page 181
Page 191
Page 206
Page 211
Page 214
Page 216
MELSEC iQ-F FX5 User's Manual (Positioning Control)
High-speed counter dedicated instructions
Rotational speed
HIOEN/DHIOEN
measurement mode
instruction
DHSCS, DHSCR,
DHSZ instruction