Step
4.
(Optional.) Configure the
destination port number for
the operation.
5.
(Optional.) Specify the string
to be filled in the payload of
each request.
6.
(Optional.) Specify the source
IPv4 or IPv6 address for the
probe packets.
7.
(Optional.) Configure the
expected data.

Configuring the UDP template

A feature that uses the UDP template performs the UDP operation to test the following items:
Reachability of a specific port on the NQA server.
Availability of the requested service on the NQA server.
In UDP template view, you can specify the expected data to be returned. If you do not specify the
expected data, the UDP operation tests only whether the client can receive the response packet from
the server.
The UDP operation requires both the NQA server and the NQA client. Before you perform a UDP
operation, configure a UDP listening service on the NQA server. For more information about
configuring the UDP listening service, see
To configure the UDP template:
Step
1.
Enter system view.
2.
Create a UDP template
and enter its view.
3.
(Optional.) Specify the
destination IP address of
the operation.
4.
(Optional.) Specify the
destination port number
for the operation.
Command
destination port port-number
data-fill string
IPv4 address:
source ip ip-address
IPv6 address:
source ipv6 ipv6-address
expect data expression [ offset
number ]
"Configuring the NQA
Command
system-view
nqa template udp name
IPv4 address:
destination ip
ip-address
IPv6 address:
destination ipv6
ipv6-address
destination port
port-number
132
Remarks
configured on the NQA server.
By default, no destination port
number is configured.
The destination port number
must be the same as the port
number of the listening service
on the NQA server.
The default payload fill string is
hexadecimal number
00010203040506070809.
By default, no source IP
address is specified.
The source IP address must be
the IP address of a local
interface, and the interface must
be up. Otherwise, no probe
packets can be sent out.
By default, no expected data is
configured.
The expected data is checked
only when you configure both
the data-fill and expect-data
commands.
server."
Remarks
N/A
By default, no UDP templates exist.
By default, no destination address is
specified.
The destination address must be the same
as the IP address of the listening service
configured on the NQA server.
By default, no destination port number is
specified.
The destination port number must be the

Hide quick links: