Verify The Configuration - HPE FlexFabric 5700 Series Network Management And Monitoring Configuration Manual

Hide thumbs Also See for FlexFabric 5700 Series:
Table of Contents

Advertisement

[DeviceA-Ten-GigabitEthernet1/0/1] quit
2.
Configure Device B:
# Specify the PTP standard as IEEE 1588 version 2.
<DeviceB> system-view
[DeviceB] ptp profile 1588v2
# Specify the clock node type as P2PTC.
[DeviceB] ptp mode p2ptc
# Enable PTP for Ten-GigabitEthernet 1/0/1.
[DeviceB] interface ten-gigabitethernet 1/0/1
[DeviceB-Ten-GigabitEthernet1/0/1] ptp enable
[DeviceB-Ten-GigabitEthernet1/0/1] quit
# Enable PTP for Ten-GigabitEthernet 1/0/2.
[DeviceB] interface ten-gigabitethernet 1/0/2
[DeviceB-Ten-GigabitEthernet1/0/2] ptp enable
[DeviceB-Ten-GigabitEthernet1/0/2] quit
3.
Configure Device C:
# Specify the PTP standard as IEEE 1588 version 2.
<DeviceC> system-view
[DeviceC] ptp profile 1588v2
# Specify the clock node type as OC.
[DeviceC] ptp mode oc
# On Ten-GigabitEthernet 1/0/1, specify the delay measurement mechanism as p2p, and
enable PTP.
[DeviceC] interface ten-gigabitethernet 1/0/1
[DeviceC-Ten-GigabitEthernet1/0/1] ptp delay-mechanism p2p
[DeviceC-Ten-GigabitEthernet1/0/1] ptp enable
[DeviceC-Ten-GigabitEthernet1/0/1] quit
4.

Verify the configuration:

# Display PTP clock information on Device A.
[DeviceA] display ptp clock
PTP profile
PTP mode
Slave only
Clock ID
Clock type
Clock domain
Number of PTP ports : 1
Priority1
: 128
Priority2
: 128
Clock quality :
Class
Accuracy
Offset (log variance) : 65535
Offset from master : 0 (ns)
Mean path delay
Steps removed
Local clock time
: IEEE 1588 Version 2
: OC
: No
: 000FE2-FFFE-FF0000
: Local
: 0
: 248
: 254
: 0 (ns)
: 0
: Sun Jan 15 20:57:29 2011