Advertisement

Step
3.
Configure the authentication
mode for multihop BFD
control packets.
4.
Set the destination port
number for multihop BFD
control packets.
5.
Set the multihop detection
time multiplier.
6.
Set the minimum interval for
receiving multihop BFD
control packets.
7.
Set the minimum interval for
transmitting multihop BFD
control packets.

Configuring a BFD template

Perform this task to specify BFD parameters in a template for sessions without next hops. You can
configure BFD parameters for LSPs and PWs through a BFD template.
To configure a BFD template:
Step
1.
Enter system view.
2.
Create a BFD template and
enter BFD template view.
3.
Configure the authentication
mode for BFD control
packets.
4.
Set the detection time
multiplier.
5.
Set the minimum interval for
receiving BFD control
packets.
6.
Set the minimum interval for
transmitting BFD control
packets.

Displaying and maintaining BFD

Execute the display command in any view and the reset command in user view.
Command
bfd multi-hop
authentication-mode { m-md5 |
m-sha1 | md5 | sha1 | simple }
key-id { cipher cipher-string |
plain plain-string }
bfd multi-hop destination-port
port-number
bfd multi-hop detect-multiplier
value
bfd multi-hop
min-receive-interval value
bfd multi-hop
min-transmit-interval value
Command
system-view
bfd template template-name
bfd authentication-mode
{ m-md5 | m-sha1 | md5 | sha1 |
simple } key-id { cipher
cipher-string | plain plain-string }
bfd detect-multiplier value
bfd min-receive-interval value
bfd min-transmit-interval value
169
Remarks
By default, no authentication is
performed.
The default setting is 4784.
The default setting is 5.
By default, the minimum interval
for receiving multihop BFD control
packets is 400 milliseconds.
By default, the minimum interval
for transmitting multihop BFD
control packets is 400
milliseconds.
Remarks
N/A
By default, no BFD template is
created.
By default, no authentication is
performed.
The default setting is 5.
By default, the minimum interval
for receiving single-hop BFD
control packets is 400
milliseconds.
By default, the minimum interval
for transmitting single-hop BFD
control packets is 400
milliseconds.