Step
9.
(Optional.) Specify the
source port number of voice
packets.
10. (Optional.) Specify the
payload size in each voice
packet.
11. (Optional.) Specify the string
to be filled in the payload of
each voice packet.
12. (Optional.) Specify the
number of voice packets to
be sent in a voice probe.
13. (Optional.) Specify the
interval for sending voice
packets.
14. (Optional.) Specify how long
the NQA client waits for a
response from the server
before it regards the
response times out.
NOTE:
Use the display nqa result or display nqa statistics command to verify the voice operation. The
display nqa history command does not display the voice operation results or statistics.

Configuring the DLSw operation

The DLSw operation measures the response time of a DLSw device.
To configure the DLSw operation:
Step
1.
Enter system view.
2.
Create an NQA operation
and enter NQA operation
view.
3.
Specify the DLSw type and
enter its view.
4.
Specify the destination IP
address of probe packets.
5.
(Optional.) Specify the
source IP address of probe
packets.
Command
source port port-number
data-size size
data-fill string
probe packet-number
packet-number
probe packet-interval
packet-interval
probe packet-timeout
packet-timeout
Command
system-view
nqa entry admin-name
operation-tag
type dlsw
destination ip ip-address
source ip ip-address
122
Remarks
no voice packets can be sent out.
By default, no source port number is
specified.
By default, the voice packet size
varies by codec type. The default
packet size is 172 bytes for
G.711A-law and G.711 µ-law codec
type, and 32 bytes for G.729 A-law
codec type.
The default payload fill string is
hexadecimal number
00010203040506070809.
The default setting is 1000.
The default setting is 20
milliseconds.
The default setting is 5000
milliseconds.
Remarks
N/A
By default, no NQA operation is
created.
N/A
By default, no destination IP
address is specified.
By default, no source IP address is
specified.
The source IP address must be the
IP address of a local interface, and
the interface must be up. Otherwise,
no probe packets can be sent out.