Step
event table.
3.
Create an entry in the
alarm table or private
alarm table.

Displaying and maintaining RMON settings

Execute display commands in any view.
Task
Display RMON statistics.
Display RMON history control
entries and history samples.
Display RMON alarm entries.
Display RMON private alarm
entries.
Display RMON event entries.
Display log information for
event entries.

RMON configuration examples

Ethernet statistics group configuration example

Network requirements
As shown in
traffic statistics for Ten-GigabitEthernet 1/0/1.
Figure 33 Network diagram
Command
security-string } [ owner text ]
Create an entry in the alarm table:
rmon alarm entry-number alarm-variable
sampling-interval { absolute | delta }
[ startup-alarm { falling | rising |
rising-falling } ] rising-threshold
threshold-value1 event-entry1
falling-threshold threshold-value2
event-entry2 [ owner text ]
Create an entry in the private alarm table:
rmon prialarm entry-number prialarm-formula
prialarm-des sampling-interval { absolute |
delta } [ startup-alarm { falling | rising |
rising-falling } ] rising-threshold
threshold-value1 event-entry1
falling-threshold threshold-value2
event-entry2 entrytype { forever | cycle
cycle-period } [ owner text ]
Command
display rmon statistics [ interface-type interface-number]
display rmon history [ interface-type interface-number ]
display rmon alarm [ entry-number ]
display rmon prialarm [ entry-number ]
display rmon event [ entry-number ]
display rmon eventlog [ entry-number ]
Figure
33, create an RMON Ethernet statistics entry on the device to gather cumulative
103
Remarks
contain entries.
By default, the RMON
alarm table and the
private alarm table do
not contain entries.
You can associate an
alarm with an event
that has not been
created yet, but the
alarm will trigger the
event only after the
event is created.