Table 16: GPON link status
UI Label
Triplexer Temp
Voltage
Figure 41: GPON alarm example, Loss of Signal
Table 17: GPON alarms
UI Label
Auto-Power Control
Failure
Loss of Signal
Loss of Link
Loss of Frame
GEM LCD
Failed Signal
Degraded Signal
Msg Error Msg
Deactivated
Disabled
Physical Equipment
Error
Description
Temperature of the triplexer device, in degrees C (and F).
Nominal triplexer operating voltage.
Description
Auto-Power Control (APC) is the ability to adjust to
variations in optical power. APC failure is the inability
to properly adjust.
No input signal detected. Make sure fiber is plugged in.
The link has been lost
Framing has been lost
Loss of GEM Channel Delineation.
Bit Error Rate exceeds 10E-5
Bit Error Rate exceeds 10E-6
Unknown PLOAM message received.
Received Deactivate on ONU.
Disabled by the OLT or the ONU Serial Number is not
configured on the OLT.
Indicates possible hardware problems.