Technical Specifications
2.
Technical Specifications
Electrical Characteristics
Power Supply Type
Operating Voltage Range
Current @ 12 V
Read Range
LED Control Input 1**
Auxiliary Input**
Auxiliary Output**
Maximum Cable Distance
to Controller
Environmental Characteristics
Operating Temp. Range
Operating Humidity Range
Outdoor Usage
* Measured using Rosslare O2S ISO cards. Range also depends on electrical
environment and proximity to metal.
** Standard configuration. Custom configurations are available.
AYC-x6355 Installation and User Manual
Linear (recommended)
6 to 16 VDC
Standby: 85 mA
Maximum: 110 mA
MIFARE Classic EV1: 40 to 45 mm (1.5 to 1.8
in.)
MIFARE Plus: 30 mm (1.2 in.)
MIFARE DESFire EV1: 30 mm (1.2 in.)
Green LED control, TTL
Buzzer control, TTL
Tamper output (open collector, active low,
max. sink current 30 mA)
Wiegand: 150 m (500 ft) with 18-AWG cable
OSDP (RS-485): 1200 m (4,000 ft) with 2x2
18-AWG twisted shielded cable
-25°C to 65°C (-13°F to 149°F)
0 to 95% (non-condensing)
Weather-resistant, meets IP65, epoxy-potted,
suitable for indoor and outdoor use