Controller Functionality
auxiliary setting defines the door open time for the second door. The
auxiliary input is used to control the indicator. If the auxiliary input is
open the door indicator flashes red; if the auxiliary input is closed the
door indicator flashes green.
This mode takes control of the Door indicator LED.
The indicator LED is not be lit when:
• A valid code is entered
• While in secure mode, when waiting for a Secondary code
8.9.11
Setting the Lockout Feature
If the controller is presented with wrong codes several times
consecutively, the unit goes into Lockout mode.
When a lockout occurs, the controller keypad and reader are locked
so no codes can be entered until the set lockout period expires.
During Lockout, Mode LED is off, Door LED flashes red, and the
controller beeps every two seconds
The default setting for the Lockout Feature is 4000 (Lockout
Disabled).
Using the lockout feature is highly recommended, especially
when selecting to use short PIN code length (4 or 5 digits).
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The Mode LED flashes green.
3. Construct a code using the
following instructions:
50
.
Mode/Transmit
Mode/Transmit
AYC-x6355 Installation and User Manual
Door/Program
Green
Door/Program
Green Green