6 Parameter Table
Par.
Name
Base
Sets the motor base frequency
T1-05
Frequency
(Hz).
T1-06 Motor Poles Sets the number of motor poles.
T1-07 Base Speed Sets the motor base speed (RPM).
Iron loss for determining the
Motor Iron
T1-11
Energy Saving coefficient.
Loss
If unknown leave it on default.
Monitor
U1-01 Frequency Reference (Hz)
U1-02 Output Frequency (Hz)
U1-03 Output Current (A)
U1-05 Motor Speed (Hz)
U1-06 Output Voltage Reference (Vac)
U1-07 DC Bus Voltage (VDC)
U1-08 Output Power (kW)
U1-09 Torque Reference (% of motor rated torque)
Input Terminal Status
Reserved
U1-10
Output Terminal Status
Reserved
U1-11
EN 38
Description
Description
: ON
: OFF
1: Digital input 1
(terminal S1 enabled)
1: Digital input 2
(terminal S2 enabled)
1: Digital input 3
(terminal S3 enabled)
1: Digital input 4
(terminal S4 enabled)
1: Digital input 5
(terminal S5 enabled)
1: Digital input6
(terminal S6 enabled)
: ON
: OFF
1: Relay Output
(terminal MA-MC closed
MB-MC open)
1: Open Collector Output 1
(terminal P1) enabled
1: Open collector Output 2
(terminal P2) enabled
YASKAWA Europe TOEP C710606 91B AC Drive L1000H - Quick Start Guide
Monitor
Drive Status
U1-12
U1-13 Terminal A1 input level
U1-14 Terminal A2 input level
Soft Starter Output (frequency after accel/
U1-16
decel ramps)
U1-18 OPE Fault Parameter
U1-24 Pulse Input frequency
Fault Trace
U2-01 Current Fault
U2-02 Previous Fault
U2-03 Frequency Reference at Previous Fault
U2-04 Output Frequency at Previous Fault
U2-05 Output Current at Previous Fault
U2-06 Motor Speed at Previous Fault
U2-07 Output Voltage at Previous Fault
U2-08 DC Bus Voltage at Previous Fault
U2-09 Output Power at Previous Fault
U2-10 Torque Reference at Previous Fault
U2-11
Input Terminal Status at Previous Fault
U2-12 Output Terminal Status at Previous Fault
U2-13 Drive Operation Status at Previous Fault
U2-14 Cumulative Operation Time at Previous Fault
U2-15 Soft-Starter Speed Reference at Previous Fault
U2-16 Motor q-Axis Current at Previous Fault
U2-17 Motor d-Axis Current at Previous Fault
Description
1: During run
1: During zero-speed
1: During REV
1: During fault reset
signal input
1: During speed agree
1: Drive ready
1: During alarm detection
1: During fault detection