400 v class, three-phase input: 3.0 to 15.0 kw. type: cimr-lc4v0007b-0011 cimr-lc4v0009b-0011 cimr-lc4v0015f-0011 cimr-lc4v0018f-0011 cimr-lc4v0024f-0011 cimr-lc4v0031f-0011
Hide thumbs Also See for L1000H:

Advertisement

Par.
Name
Flow at
100cSt & at
P1-11
max. pres-
Pump data:
sure
refer to the parameter data supplied
Flow at
with the valve package or use the
100cSt & at
following web page to calculate the
P1-12
max. pres-
values:
sure
http://www.blain.de/calc
Pump Rated
P1-13
Speed
Flow at
Pump data
empty car
P1-14
For valves from manufacturer
pressure &
"Blain Hydraulics GmbH", use cal-
at 100cSt
culation tool in the internet:
Flow at 1
http://www.blain.de/calc
bar pres-
or the iPhone App "Blain Calcula-
P1-15
sure & at
tor"
100cSt
Nominal
P1-16
Elevator data
Speed
Intermedi-
P1-17
Elevator data
ate Speed
Inspection
P1-18
Elevator data
Speed
Leveling
P1-19
Elevator data
Speed
Down Travel Control
Down Con-
trol Initial-
P2-01
ization
Enables down travel control
Tempera-
ture
Determines the minimum pump
Down
frequency during down travel con-
P2-03
Energy Fac-
trol. Modes:
tor
P2-03 = 0.0 Energy Saving
P2-03 > 0.0 Normal
Down
Time for calculated acceleration
P2-04
Ramp Time
ramp 1 during down travel control
1
sequence.
Down
Time for calculated acceleration
P2-06
Ramp Time
ramp 2 during down travel control
2
sequence.
YASKAWA Europe TOEP C710606 91B AC Drive L1000H - Quick Start Guide
Description
Par.
Name
Down
Decelera-
Factor for adjusting the decelera-
P2-07
tion Fre-
tion frequency level in down travel
quency
control.
Gain
Down
Speed
Torque reference value for Down
P2-08
Torque Ref-
Travel Control
erence
Down
Torque
Gain value, applied to the torque
P2-09
Gain Cor-
gain in case of down travel control.
rection Fac-
tor
Down Tem-
perature
Gain value, applied to the tempera-
P2-10
Gain Cor-
ture gain in case of down travel
rection Fac-
control.
tor
Down
Decelera-
Gain value, applied to the pump
P2-11
tion Leak-
leakage at deceleration.
age Gain
Down Lev-
eling Con-
Wait time for leveling travel con-
P2-12
trol Wait
trol.
Time
Down Lev-
eling Con-
Step frequency for leveling travel
P2-13
trol Step
control.
Frequency
Down level-
Step time for leveling travel con-
P2-14
ing control
trol.
step time
S Curve
Characteris-
S curve characteristic 2 at decelera-
P2-15
tic 2 at
tion start.
Decel Start
S Curve
Characteris-
S curve characteristic 2 at decelera-
P2-16
tic 2 at
tion end.
Decel End
S Curve
Characteris-
S curve characteristic 3 at decelera-
P2-17
tic 3 at
tion start.
Decel Start
6 Parameter Table
Description
EN 35