Download Print this page

YASKAWA L1000H Quick Start Manual page 47

400 v class, three-phase input: 3.0 to 15.0 kw. type: cimr-lc4v0007b-0011 cimr-lc4v0009b-0011 cimr-lc4v0015f-0011 cimr-lc4v0018f-0011 cimr-lc4v0024f-0011 cimr-lc4v0031f-0011
Hide thumbs Also See for L1000H:

Advertisement

Wire Gauge
2
mm
(AWG)
3.5/5.5
(12/10)
8
(8)
14
(6)
22
(4)
30/38
(3/2)
<1> Use the specified crimp terminals (Model No.:14-NK4) when using LC4V0018 with the wire 14
mm
(AWG:6).
2
Note: Use crimp insulated terminals or insulated tubing for wiring these connections.
Wires should have a continuous maximum allowable temperature of 75C 600 V
UL approved vinyl sheathed insulation. Ambient temperature should not exceed
30 C.
Input Fuse Selection
Use the fuses listed up in the table on
YASKAWA Europe TOEP C710606 91B AC Drive L1000H - Quick Start Guide
Terminal Screws
M4
M5
M6
M8
M4
M5
M6
M8
M4
M5
M6
M8
M6
M8
M8
page 12
8 Instructions for UL and cUL
Crimp Terminal
Model Number
R5.5-4
R5.5-5
R5.5-6
R5.5-8
8-4
R8-5
R8-6
R8-8
14-4
R14-5
R14-6
R14-8
R22-6
R22-8
R38-8
when wiring the main circuit.
Tightening Torque
Nm
(lbin.)
1.2 to 1.5
(10.6 to 13.3)
2.0 to 2.5
(17.7 to 22.1)
4.0 to 5.0
(35.4 to 44.3)
9.0 to 11.0
(79.7 to 97.4)
1.2 to 1.5
(10.6 to 13.3)
2.0 to 2.5
(17.7 to 22.1)
4.0 to 5.0
(35.4 to 44.3)
9.0 to 11.0
(79.7 to 97.4)
1.2 to 1.5
(10.6 to 13.3)
2.0 to 2.5
(17.7 to 22.1)
4.0 to 5.0
(35.4 to 44.3)
9.0 to 11.0
(79.7 to 97.4)
4.0 to 5.0
(35.4 to 44.3)
9.0 to 11.0
(79.7 to 97.4)
9.0 to 11.0
(79.7 to 97.4)
EN 47

Hide quick links:

Advertisement

loading