Download Print this page

Electrical Installation - YASKAWA L1000H Quick Start Manual

400 v class, three-phase input: 3.0 to 15.0 kw. type: cimr-lc4v0007b-0011 cimr-lc4v0009b-0011 cimr-lc4v0015f-0011 cimr-lc4v0018f-0011 cimr-lc4v0024f-0011 cimr-lc4v0031f-0011
Hide thumbs Also See for L1000H:

Advertisement

3

Electrical Installation

The figure below shows the main and control circuit wiring.
Main Switch
Fuse
R/L1
S/L2
T/L3
Three-phase
Forward Run
power supply
380 to 480 VAC
Not assigned
50/60 Hz
Down Travel Speed
Nominal Speed Sel.
Digital Inputs
Intermediate Speed Sel.
Inspection Speed Sel.
Temp. Converter In
Analog Inputs
Not assigned
Analog common
MEMOBUS/Modbus
comm. RS485/422
max. 115.2 kBps
Safe Disable Inputs
YASKAWA Europe TOEP C710606 91B AC Drive L1000H - Quick Start Guide
+2
+1
R/L1
EMC
L1000H
S/L2
Filter
T/L3
S1
S2
S3
S4
S5
S6
+24 V
Sink
SC
Source
0 V
Shield ground terminal
RP
Pulse Train Input (max. 32 kHz)
+V
Power Supply +10.5 VDC, max. 20 mA
A1
Analog Input 1
0 to +10 VDC (20 kΩ)
A2
Analog Input 2
0 to +10 VDC (20 kΩ)/
0/4 to 20 mA (250 Ω)
AC
0 V
Termination Resistor
(120 Ω, 1/2 W)
DIP Switch S2
R+
S+
S-
IG
H1
H2
HC
B1
B2
U/T1
V/T2
W/T3
Terminal board jumper
and switch
CIMR-LCxV
DIP Switch S1
V
I
A2 Volt/Curr Sel.
DIP Switch S2
Off
On
Term. Res. On/Off
DIP Switch
S3
0 V
E (G)
3 Electrical Installation
Motor Contactors
(1 or 2)
Shielded Cable
Ground
MA
Relay Output 1
250 VAC, max. 1 A
MB
Fault
30 VDC, max. 1 A (min. 5 VDC, 10 mA)
MC
Safe Disable
Photo Coupler 1
P1
Status (STO)
5 to 48 VDC, 2 to 50 mA
P2
Speed agree
Photo Coupler 1
5 to 48 VDC, 2 to 50 mA
PC
Photo Coupler
Common
AM
Output freq.
AC
+
Multi-function analog output AM
0 to +10 VDC (2 mA)
MP
Not assigned
Pulse Train Output
0 to 32 kHz
Shielded Line
Twisted-pair shielded line
Control Circuit Terminal
Main Circuit Terminal
U
Motor
V
M
W
EN 11

Hide quick links:

Advertisement