6 Parameter Table
Par.
Name
Analog Input Setting
AM
Enter value equal to U1-
H4-01
Monitor
monitor values. Example: Enter
Selection
"103" for U1-03.
Sets terminal AM output voltage
H4-02 AM Gain
equal to 100% monitor value.
Sets terminal AM output voltage
H4-02 AM Bias
equal to 0% monitor value.
Pulse Output Setting
Enter value equal to U-
MP Monitor
H6-06
monitor values. Example: Enter
Sel.
"102" for U1-02.
MP Monitor
Sets the number of output pulses
H6-07
Scaling
when the monitor is 100% (in Hz).
Motor Overheat Protection
Sets the motor overload protection.
Motor
0:Disabled
L1-01
Overload
1:Standard fan cooled motor
Prot. Sel.
2:Standard blower cooled motor
3:Vector motor
Motor
Sets the motor overload protection
L1-02
Overload
time in min. Normally no change is
Prot. Time
necessary.
Stall Prevention
0:Disabled - Motor accelerates at
active acceleration rate and may
Stall
stall with too heavy load or too
Prevention
short accel time.
Selection
L3-01
1:General Purpose - Hold
during
acceleration when current is
Accelera-
above L3-02.
tion
2:Intelligent - Acceleration in the
shortest possible time.
Stall Prev.
Sets the current level for stall pre-
L3-02
Level dur-
vention during acceleration.
ing Accel.
Stall Prev.
0:Disabled - Deceleration as set.
Selection
OV might occur.
L3-04
during
1:General Purpose - Deceleration is
Decel.
hold if DC bus voltage rises high.
0:Disabled - Motor stall or
Stall Prev.
overload might occur.
L3-05
Selection
1:Decel Time 1 - Reduce speed
during Run
using C1-02.
EN 34
Description
YASKAWA Europe TOEP C710606 91B AC Drive L1000H - Quick Start Guide
Par.
Name
Stall Prev.
Sets the current level at which stall
L3-06
Level dur-
prevention during run starts to
ing Run
operate.
Torque Limit
L7-01
Torque
Available in Customer Access
to
Limit
Level.
L7-04
Ambient Temperature
Ambient
Available in Customer Access
L8-12
Tempera-
Level.
ture
User Default
User
Available in Customer Access
o2-03
Default
Level.
Selection
Copy Function
o3-01
Copy Func-
Available in Customer Access
o3-02
tion
Level.
Input Data - Teaching Function
0: Manual Setting,
Hydraulic
1: ISO VG 22,
P1-01
Oil ISO VG
2: ISO VG 32,
Number
3: ISO VG 46,
4: ISO VG 68
Tempera-
P1-02
ture at
Manual or preselected by P1-01
100 cSt
Tempera-
P1-03
ture at 25
Manual or preselected by P1-01
cSt
Ram Diam-
P1-04
Elevator data
eter
Number of
P1-05
Elevator data
rams
Suspension
P1-06
Elevator data
ratio
Empty car
P1-07
static pres-
Elevator data
sure
P1-08 Pay load
Elevator data
Dynamic
P1-09
pressure
Elevator data
increase
Description

Hide quick links:

Advertisement

loading