8 Instructions for UL and cUL
Low Voltage Wiring for Control Circuit Terminals
Wire low voltage wires with NEC Class 1 circuit conductors; refer to national state or local
codes for wiring. Use a class 2 (UL regulations) power supply for the control circuit termi-
nal.
Input / Output
Multi-function photocoupler outputs
Multi-function digital inputs
Multi function analog inputs
Pulse train output
Drive Short-Circuit Rating
This drive has undergone the UL short-circuit test, which certifies that during a short circuit
in the power supply the current flow will not rise above 30,000 Amps maximum at 240 V for
200 V class drives and 440 V for 400 V class drives.
• The MCCB and breaker protection and fuse ratings (refer to the preceding table) shall be
equal to or greater than the short-circuit tolerance of the power supply being used.
• Suitable for use on a circuit capable of delivering not more than 30,000 RMS symmetrical
amperes for 240 V in 200 V class drives (up to 440 V for 400 V class drives) motor over-
load protection
 Drive Motor Overload Protection
Set parameter E2-01 (motor rated current) to the appropriate value to enable motor overload
protection. The internal motor overload protection is UL listed and in accordance with the
NEC and CEC.
E2-01 Motor Rated Current
Setting Range: Model Dependent
Factory Default: Model Dependent
The motor rated current parameter (E2-01) sets the current value that is used as a base for
motor protection. The motor protection parameter L1-01 is set as factory default. Set E2-01
to the full load amps (FLA) stamped on the nameplate of the motor.
The operator must enter the rated current of the motor (T1-04) in the menu during auto-tun-
ing. If the auto-tuning operation completes successfully (T1-02 = 0), the value entered into
T1-04 will automatically write into E2-01.
EN 48
Control Circuit Terminal Power Supply
Terminal Signal
P1, P2, PC
S1, S2, S3, S4,
S5, S6, SC
+V, A1, A2, AC
MP
YASKAWA Europe TOEP C710606 91B AC Drive L1000H - Quick Start Guide
Power Supply Specifications
Requires class 2 power supply.
Use the internal LVLC power supply of the drive.
Use class 2 for external power supply.
Use the internal LVLC power supply of the drive.
Use class 2 for external power supply.
Use the internal LVLC power supply of the drive.
Use class 2 for external power supply.