YASKAWA L1000H Quick Start Manual page 37

400 v class, three-phase input: 3.0 to 15.0 kw. type: cimr-lc4v0007b-0011 cimr-lc4v0009b-0011 cimr-lc4v0015f-0011 cimr-lc4v0018f-0011 cimr-lc4v0024f-0011 cimr-lc4v0031f-0011
Hide thumbs Also See for L1000H:

Advertisement

Par.
Name
Minimum
Tempera-
Sets the lower limit for the amount
P5-04
ture Com-
of compensation.
pensation
Dwell Functions
Special
Dwell Fre-
Refer to drawings in section Start
P6-01
quency Off-
Up
set
Special
Used when Nominal, Intermediate
P6-02
Dwell Time
or Inspection Speed is selected
1
Special
P6-03
Dwell Time
Used for re-leveling operation
2
Special
Dwell at
Gain applied to leakage at Start-
Start Leak-
P6-05
Dwell (used for re-leveling opera-
age Multi-
tion)
plier for Re-
Leveling
Stop Dwell
Gain applied to leakage at Stop
P6-06
Leakage
Dwell (used for all speed opera-
Multiplier
tions)
Stop Dwell
P6-07
Time setting for Dwell at stop
Time
Leveling Control Functions
Leveling
When Leveling time exceeds this
P7-01
Control
value, Leveling speed is increased
Wait Time
as described below.
Leveling
Step width for increasing frequency
P7-02
Control Fre-
by Leveling Control Function
quency Step
Leveling
Wait time for increasing frequency
P7-03
Control
by Leveling Control
Step Time
Leveling
Upper limit for Leveling frequency,
P7-05
Control
increased by Leveling Control
Upper Limit
Function
Special Tuning
Tempera-
Higher values increase the compen-
P8-01
ture Gain
sation amount.
Torque
Higher values increase the compen-
P8-02
Gain
sation amount.
YASKAWA Europe TOEP C710606 91B AC Drive L1000H - Quick Start Guide
Description
Par.
Name
Torque Ref-
erence
Higher values increase the compen-
P8-03
Compensa-
sation amount.
tion Gain
Leveling
Speed Mul-
Factor for adapting leveling speed
P8-04
tiplier for
reference in case of re-leveling
Re-Level-
operation.
ing
Gain for
Gain, applied to automatic deceler-
P8-05
Leveling
ation delay time.
delay Time
Torque Ref-
Additional gain value for adjusting
erence
P8-06
torque reference in overload condi-
Overload
tion.
Gain
Sets the current level for triggering
Overload
P8-07
overload travel function. Set in per-
Current
cent of the drive's rated current.
Sets the time the output current
Overload
must be above P8-07 for triggering
P8-08
Detection
overload function.
Time
P8-08 = 0 disables overload func-
tion.
SEQF fault will occur during
deceleration to leveling speed when
opening RUN command while soft-
starter output (U1-16) is higher
SEQF
than [(P3-04 + Temperature com-
P8-11
Detection
pensation value + Torque compen-
Gain
sation value) × P8-11]
SEQF is detected only if Nominal
or Intermediate speed is selected in
Up travel.
Auto-Tuning
Rotational Auto-Tuning
Auto-Tun-
2: Terminal resistance only
T1-01
ing Mode
3: Rotational Auto-Tuning for
Selection
Energy Saving
Rated
T1-02
Sets the motor rated power (kW).
Power
Rated
T1-03
Sets the motor rated voltage (V).
Voltage
Rated
T1-04
Sets the motor rated current (A).
Current
6 Parameter Table
Description
EN 37