11 MANUAL CONTROL

11.2.4 Creating start programs for JOG operation

Setting item
Inching movement
Cd.16
amount
Cd.17 JOG speed
Refer to section "5.7 List of control data" for details on the setting details.
Interface
signal
External
signal
A sequence program must be created to execute a JOG operation. Consider the
"required control data setting", "start conditions" and "start time chart" when creating
the program.
The following shows an example when a JOG operation is started for axis 1.
("
Cd.17
JOG speed" is set to "100.00mm/min" in the example shown.)
Required control data setting
The control data shown below must be set to execute a JOG operation. The
setting is carried out with the sequence program.
Setting
value
0
Set "0".
Set a value equal to or below the " Pr.31
10000
JOG speed limit value".
Start conditions
The following conditions must be fulfilled when starting. The required conditions
must also be assembled in the sequence program, and the sequence program
must be configured so the operation will not start if the conditions are not fulfilled.
Signal name
PLC READY signal
QD75 READY signal
All axis servo ON
Synchronization flag
Axis stop signal
Start complete signal
BUSY signal
Error detection signal
M code ON signal
Stop signal
Upper limit (FLS)
Lower limit (RLS)
1 If the PLC CPU is set to the asynchronous mode in the synchronization setting, this must be
inserted in the program for interlocking. If it is set to the synchronous mode, it must not be
inserted in the program for interlocking because it is turned ON when the PLC CPU executes
calculation.
2
If the operation is stopped by the limit switch "OFF", JOG operation can be carried out in the
direction in which the limit switch turns ON.
Setting details
Signal state
ON PLC CPU preparation completed
ON QD75 preparation completed
ON All axis servo ON
QD75 buffer memory
1
ON
The access is possible.
OFF Axis stop signal is OFF
OFF Start complete signal is OFF
OFF QD75 is not operating
OFF There is no error
OFF M code ON signal is OFF
OFF Stop signal is OFF
2
ON Within limit range
2
ON Within limit range
11 - 10
MELSEC-Q
Buffer memory address
Axis
Axis
Axis
Axis
1
2
3
4
1517 1617 1717 1817
1518
1618
1718
1818
1519
1619
1719
1819
Device
Axis
Axis
Axis
Axis
1
2
3
4
Y0
X0
Y1
X1
Y4
Y5
Y6
Y7
X10 X11 X12 X13
XC
XD
XE
XF
X8
X9
XA
XB
X4
X5
X6
X7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd75m2Qd75m4

Table of Contents