9 MAJOR POSITIONING CONTROL
Setting item
Da.1 Operation pattern
Da.2 Control system
Acceleration time
Da.3
No.
Deceleration time
Da.4
No.
Axis to be
Da.5
interpolated
Positioning address/
Da.6
movement amount
Da.7 Arc address
Da.8 Command speed
Da.9 Dwell time
Da.10
M code
Refer to section "5.3 List of positioning data" for information on the setting details.
Positioning data setting examples
[Reference axis and interpolation axis are designated as axis 1 and axis 2,
respectively.]
The following table shows setting examples when "2-axis circular interpolation
control with center point designation (ABS right arc, ABS left arc)" is set in
positioning data No. 1 of axis 1. (The required values are also set in positioning
data No. 1 of axis 2.)
Axis 1
Axis 2
Axis
(reference
(interpolation
axis) setting
axis) setting
example
example
Termination
ABS circular
right
ABS circular
left
1
0
2
8000.0 µ m
6000.0 µ m
4000.0 µ m
3000.0 µ m
6000.00
mm/min
500ms
10
POINT
Set a value in "
Da.8
Command speed" so that the speed of each axis does not
Pr.8
exceed the "
Speed limit value". (The speed limit does not function for the
speed calculated by the QD75 during interpolation control.)
Set "Termination" assuming the next positioning data will not
be executed.
Set absolute system, 2-axis circular interpolation control with
center point designation. (Select clockwise or
counterclockwise according to the control.)
Designate the value set in " Pr.25
the acceleration time at start.
Designate the value set in " Pr.10
the deceleration time at deceleration.
Set the axis to be interpolated (partner axis).
If the self-axis is set, an error will occur.
Set the positioning address. (Assuming "mm" is set in
" Pr.1
Unit setting".)
Set the arc address. (Assuming that the " Pr.1
setting" is set to "mm".)
Set the speed when moving to the end point address.
(Designate the composite speed in " Pr.20
speed designation method".)
Set the time the machine dwells after the positioning stop
(pulse output stop) to the output of the positioning complete
signal.
Set this when other sub operation commands are issued in
combination with the No. 1 positioning data.
9 - 63
MELSEC-Q
Setting details
Acceleration time 1" as
Deceleration time 0" as
Interpolation
Unit